Development proposed is: Erect extension to existing annex, flue
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Green Belt Policy
Residential Amenity
Policy Weight
Inspector’s Reasoning
Appeal Decision
Site visit made on 3 August 2026
by D R Kay BA Dip.Arch RIBA(Retired)
an Inspector appointed by the Secretary of State
Decision date: 24 August 2026
Appeal Ref: 6007369
38 Brook Lane, Corfe Mullen, Wimbourne, Dorset BH21 3RD
• The appeal is made under section 78 of the Town and Country Planning Act 1990 (as amended)
against a refusal to grant planning permission.
• The appeal is made by Jacquie Upton against the decision of Dorset Council.
• The application Ref is P/HOU/2025/06963.
• The development proposed is: Erect extension to existing annex, flue.
Decision
1. The appeal is dismissed.
Preliminary Matters
2. The description of development was changed by the Council from that included on
the application form. Whilst not being consulted, the appellant has raised no
objection to the change. I have therefore used the Council’s revised description in
the header above, as it more accurately describes the extent of development.
3. A revised National Planning Policy Framework was published on 17 August 2026
(the Framework 2026). Whilst this made certain revisions to aspects of national
planning policy, having examined the Framework 2026 in respect of the matters
relied on by the main parties, I find these are substantially unchanged. I have
therefore determined the appeal in accordance with the revised Framework 2026.
Main Issues
4. The appeal site is located within the South-East Dorset Green Belt; the main
issues therefore are:
• whether the proposal would be inappropriate development in the Green Belt
(the GB) for the purposes of the development plan and the Framework 2026
including the effect upon the openness of the Green Belt; and
• if the proposal is found to be inappropriate development, whether the harm
by reason of inappropriateness, and any other harm, is clearly outweighed by
other considerations so as to amount to the very special circumstances
required to justify the development.
Reasons
Whether or not the development would be inappropriate
5. The appeal property consists of a large, almost square two-storey dwelling,
together with a single storey rectangular shaped former garage building, which has
Appeal Decision 6007369
2
previously been converted to a two-bedroom annexe. The appeal property sits
within a large rectangular plot, the main dwelling occupying a central location,
whilst the annexe building sits to the side and in front of the principal elevation of
the main dwelling, attached to it via a high masonry wall, through which a gate
provides access from the property’s front forecourt to the rear garden.
6. The proposal seeks to erect a small extension within the corner between the main
dwelling and the annexe to provide a dedicated living room. The proposal does not
seek to create an internal link between the two elements of the property, which
would remain as two elements within a single residential planning unit.
7. Development within the GB is controlled by saved Policy GB3 of the East Dorset
Local Plan 2002 (the Saved Local Plan), and Policy KS3 of the Christchurch and
East Dorset Local Plan Part 1 – Core Strategy 2014 (the Core Strategy). The latter
policy relates to the strategic control of GB within the development plan area, whilst
the former provides specific policy relating to extensions and replacement dwellings
in the GB.
8. Policy GB6 of the Framework 2026 states that development in the GB is
inappropriate unless it falls within one of the categories in policy GB7. It goes on to
state that inappropriate development is, by definition, harmful to the GB and should
not be approved except in very special circumstances. Such circumstances will not
exist unless the potential harm to the GB by reason of inappropriateness and any
other harm resulting from the proposed development, is clearly outweighed by
other considerations. In making this assessment, substantial weight should be
given to the harm to the GB which would be caused, including harm to its
openness.
9. The primary issue is to determine if the proposal would represent inappropriate
development in the Green Belt. Policy GB7 of the Framework 2026 sets out
exceptions to inappropriate development. I find the site would not comply with
exceptions GB7(1)(a), GB7(1)(c), GB7(1)(d), GB7(1)(f), GB7(1)(g) or GB7(1)(h).
With regards to GB7(1)(e) - the redevelopment of previously developed land (PDL),
the site is within the garden curtilage of a residential dwelling. As such, it would not
meet the definition of PDL in Annex B of the Framework 2026. I find it would,
therefore, not meet the GB7(1)(g) exception.
10. With regards to the exception at paragraph GB7(1)(b), this relates to the extension
or alteration of a building, provided that it does not result in disproportionate
additions over and above the size of the original building. For the purposes of the
policy GB7(1)(b) exception, the ‘original building’ is defined in Footnote 40 as ‘the
building that existed on 1 July 1948 or, if constructed after 1 July 1948, as it was
built originally’.
11. The evidence identifies that the original main dwelling was a single-storey dwelling
with a detached double garage. The main dwelling received permission from the
Council in 1987 for the addition of a further storey, extending the property upwards
to create a two-storey dwelling to its full footprint. The evidence does not identify if
the original bungalow had any accommodation within the roof space, but on the
basis of creating another full storey height, to its full perimeter, the original main
dwelling was substantively doubled in size.
12. Subsequently, the double garage received permission in 1993 for a substantial
extension to create a four-car garage, its footprint increasing by around 110%. This
Appeal Decision 6007369
3
enlarged garage block, in incidental use to the main dwelling, was further granted
permission in 2021 for its conversion to residential accommodation ancillary to the
main dwelling house.
13. Cumulatively, the floor area of the original building has therefore already been
enlarged by significantly more than 100% from its original residential floorspace.
The proposal would seek further development, which taken in combination with the
development which has already taken place, I find would represent disproportionate
additions, over and above the size of the original building. I therefore find that it
would not benefit from the exception to inappropriateness provided by policy
GB7(1)(b) of the Framework 2026.
14. Written Policy GB3 contained in paragraph 6.104 of the Saved Local Plan, does not
specifically place a restriction on the size of extensions. However, within the
preceding paragraphs 6.99 to 6.103, it acknowledges that it would clearly be
contrary to the purpose of the GB to allow a succession of ‘limited’ extensions
which cumulatively form a substantial extension to an existing dwelling. This
acknowledges that Government advice and general policy towards development in
the GB at the time (Planning Policy Guidance 2 Green Belts (DETR, 1995)
(PPG2)), permit ‘limited’ but not ‘disproportionate’ extensions. This accords with the
thrust of policy GB7(1)(b) of the Framework 2026.
15. Assessed against the wording of Policy GB3 in isolation, as a single-storey
extension of limited floor area, height and bulk, the proposed extension would not
dominate the existing dwelling. This would in part be due to its limited size, the
overall size of the buildings that currently occupy the site and its location within an
internal corner, where the main dwelling and annexe are at their closest points to
each other. The proposed development would also be substantially screened from
within views from the public realm.
16. However, I find the proposal would change the visual impact of the dwelling on the
openness of the Green Belt through an increase in its built form, resulting in harm.
The proposal would also create some loss of openness, by the development of
previously undeveloped land within the Green Belt, which would also result in some
spatial harm through encroachment. I would classify both these harms as being
moderate. However, policy GB6(2) of the Framework 2026 requires that substantial
weight is given to any harm to the Green Belt, including harm to its openness.
17. For the above reasons, I therefore conclude that the proposal would conflict with
Policy GB3 of the Saved Local Plan and Policy KS3 of the Core Strategy. It would
also constitute inappropriate development in the Green Belt.
Other Considerations
18. Whilst I have found harm to the openness of the Green Belt, the proposal would be
of an acceptable design in relation to layout, site coverage, architectural style, bulk,
height, materials, landscaping and other visual impact. It would be sympathetic to
the character and appearance of the surrounding area. The proposal would also
raise no conflicts with overlooking or loss of privacy impacts to the occupants of
neighbouring properties. I therefore find it would accord with the criteria contained
in Policy HE2 of the Core Strategy.
19. The appellant has stated that the reason for the proposal is to provide additional
accommodation to allow for multi-generational living. It is understood that this
Appeal Decision 6007369
4
would facilitate support for someone with a protected characteristic. However, the
existing annexe already provides two bedrooms, a bathroom and a large, combined
kitchen, dining and lounge area. It is therefore already capable of providing
independent living facilities for occupants of two separate bedrooms.
20. The proposal would add a separate larger lounge area, together with a combined
utility/bathroom area. There is no evidence before me that the needs of the person,
or persons, with protected characteristics have mobility issues which require
additional circulation space, that would provide justification for the further increase
in the lounge and dining area. Similarly, it has not been identified that the person
requires permanent live-in support, that would prevent one of the two bedrooms
from being used as lounge facilities.
21. I have therefore given due regard to the Public Sector Equality Duty for persons
with protected characteristics under s149 of the Equality Act 2010. However, I
consider that the harm to the openness of the GB from the proposal, outweighs the
benefit to the appellant in this case.
22. The appellant’s agent has suggested that the appellant could enact larger
extensions to the existing dwelling through exercise of their rights under the Town
and Country Planning (General Permitted Development) (England) Order 2015 (as
amended) (the GPDO). There is no evidence before me to determine if the rights
under the GPDO are available to the appellant, or if they have previously been
restricted by condition or other Article 4 Direction by the Council. It is therefore not
clear that there would be a real prospect of the suggested development occurring
under the GPDO. I have therefore given this little weight in my determination of the
appeal.
Green Belt Balance and Conclusion
23. The proposal would constitute inappropriate development in the Green Belt,
resulting in harm to its openness. Accordingly, the Framework 2026 requires that
substantial weight is given to any harm to the Green Belt, including harm to its
openness, and that inappropriate development should not be approved except in
very special circumstances. Very special circumstances will not exist unless the
harm to the Green Belt and any other harm, is clearly outweighed by other
considerations. I conclude that the other considerations in this case, are not
sufficient to comprise the very special circumstances necessary to justify the
approval of this proposal. The proposal is contrary to Policy GB3 of the East Dorset
Local Plan 2002, and Policy KS3 of the Christchurch and East Dorset Local Plan
Part 1 – Core Strategy 2014, which seek to protect the Green Belt.
24. I have considered all other matters raised, but none outweigh the conclusions I
have reached. For the reasons set out above, the appeal is dismissed.
David Kay
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.