Erection of part two storey, part single storey rear extension, entrance alterations, garage conversion and internal alterations
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Residential Amenity
Character & Appearance
Extensions
Inspector’s Reasoning
Appeal Decision
Site visit made on 26 January 2026
by N Robinson BA (Hons) MA MRTPI
an Inspector appointed by the Secretary of State
Decision date: 30 January 2026
Appeal Ref: 6001371
2 Sandringham Close, Coventry CV4 8JR
• The appeal is made under section 78 of the Town and Country Planning Act 1990 (as amended)
against a refusal to grant planning permission.
• The appeal is made by Mr Vinod Menon against the decision of Coventry City Council.
• The application Ref is PL/2025/0001036/HHA,
• The development proposed is erection of part two storey, part single storey rear extension, entrance
alterations, garage conversion and internal alterations .
Decision
1. The appeal is dismissed.
Main Issues
2. The main issues are the effect of the proposal on:
- the living conditions of the occupiers of neighbouring properties 10 and 14
Highgrove with particular regard to overlooking; and
-the character and appearance of the host dwelling and the surrounding area.
Reasons
Living conditions
3. 2 Sandringham Close is a large, detached dwelling which borders the rear
elevations of Nos 10,12 and 14 Highgrove to the rear and western side elevation.
The property is elevated above the dwellings to the rear and at my site visit I
observed that there is limited boundary vegetation to the rear site boundary. The
proposal includes a part 2-storey, part single storey rear extension which would
contain windows in the rear and side elevations.
4. The Householder Design Guide Supplementary Planning Document (2023) (SPD)
states that for 2-storey rear extensions a minimum rear to rear windows distance
of at least 20m should be retained and any side facing windows above ground
level should be obscure glazed to prevent overlooking.
5. The first-floor side window would face the windowed rear elevation of 14
Highgrove and its rear garden, where it would result in opportunities for the
overlooking of these spaces. Nonetheless, noting that this window serves a walk-in
wardrobe, I am satisfied that this could be addressed through the imposition of a
condition requiring that this window is obscurely glazed.
Appeal Decision 6001371
2
6. The Council states that there is an existing separation of approximately 21m
between the rear elevations of the existing dwelling and 10 Highgrove, which
accords with the minimum separation distances for rear-facing windows in the
SPD. The proposed rear-facing windows would be sited approximately 18m from
the rear elevation of No 10. This would fall below the minimum separation distance
set down in the SPD. This shortfall, in combination with the elevated nature of the
appeal property and the lack of screening from intervening vegetation, would result
in a harmful level of overlooking of No 10 and its rear garden from the first-floor
bedroom window which would go beyond existing and reasonable levels, resulting
harm to the living conditions of the occupiers of this property.
7. The proposal would result in harm to the living conditions of the occupiers of 10
Highgrove through overlooking. Conflict thus arises with those aims of policy DE1
of the Local Plan (2017) (LP) which seek to ensure that development respects and
enhances its surroundings. Conflict also arises with the SPD which seeks to
ensure that extensions do not result in a material loss of amenity to neighbouring
properties as a result of, amongst other matters, the erosion of privacy.
Character and appearance
8. The property is a large, modern 2-storey detached red brick dwelling with a wide
projecting gable and a hipped roof. Whilst there are subtle variations in dwelling
designs within the cul-de-sac, including in fenestration and roof form, Sandringham
Close is characterised by the similarity and cohesiveness of dwelling forms. Some
of the properties within Sandringham Close have porches formed within a recess
within or between projecting gables, however, pitched roof porches projecting
beyond the principal elevation are not a characteristic of Sandringham Close. The
consistency in the form of dwellings results in a pleasant, cohesive suburban
character and appearance, to which the appeal property makes a positive
contribution. The proposal includes a pitched roof porch to the front elevation.
9. The porch would be constructed in materials to match the host dwelling, would
have a roof profile which would be consistent with the host property and would
retain a clear separation between the porch and the bay window. Whilst sizeable,
given the scale of the host dwelling the porch would not dominate the host
dwelling. Given this, I am satisfied that no harm would arise to the character and
appearance of the host dwelling. Nonetheless, projecting pitched roof porches are
not characteristic of the immediate surroundings and the porch would be readily
apparent in street scene views where it would compromise the cohesiveness of
the street scene, resulting in harm to the established character and appearance of
the area.
10. The proposal would result in harm to the character and appearance of the
surrounding area. It would thus conflict with those aims of LP policy DE1 which
seek to ensure that development respects and enhances its surroundings and
positively contribute towards the local identity and character of an area.
Other Matters
11. Reference is made to developments at 4 Sandringham Close and 14 Highgrove.
There is limited information regarding these developments before me,
nonetheless, they do not appear to include a projecting porch and there is no
indication that they had a harmful effect on the living conditions of the occupiers of
Appeal Decision 6001371
3
neighbouring properties. These developments do not therefore weigh in favour of
the proposal.
Conclusion
12. For the reasons given above, I conclude that the appeal should be dismissed.
N Robinson
INSPECTOR