Rear/side extensions with first floor rear extension and internal alterations
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Extensions
Character & Appearance
Residential Amenity
Inspector’s Reasoning
Appeal Decision
Site visit made on 21st October 2025 by E Nutman BA (Hons)
Decision by M Russell BA (Hons) DipTP MRTPI
an Inspector appointed by the Secretary of State
Decision date: 2 January 2026
Appeal Ref: 6000394
106 Cranham Gardens, Upminster RM14 1JN
• The appeal is made under section 78 of the Town and Country Planning Act 1990 (as amended)
against a refusal to grant planning permission.
• The appeal is made by Mr & Mrs Smith against the decision of the Council of the London Borough of
Havering.
• The application Ref is P0134.25
• The development proposed was originally described as ‘rear/side extensions with first floor rear
extension and internal alterations’.
Decision
1. The appeal is allowed and planning permission is granted for part single, part two
storey side/rear extension and internal alterations with changes/additions to the
fenestration and doors at 106 Cranham Gardens, Upminster RM14 1JN in
accordance with the terms of the application, Ref P0134.25, subject to the following
conditions:
1) The development hereby permitted shall begin not later than three years from
the date of this decision.
2) The development hereby permitted shall be carried out in accordance with the
following approved plans: Drawing Nos 01-C and 03-C.
3) The external materials of the extension hereby permitted shall match those
used in the existing building.
4) Notwithstanding the provisions of the Town and Country Planning (General
Permitted Development) (England) Order 2015, no window or other opening
(other than those shown on the approved plans) shall be formed in the flank
walls of the extensions hereby permitted, unless specific permission under the
provisions of the Town and Country Planning Act 1990 has first been sought
and obtained in writing from the Local Planning Authority.
Appeal Procedure
2. The site visit was undertaken by a representative of the Inspector whose
recommendation is set out below and to which the Inspector has had regard before
deciding the appeal.
Procedural Matter
3. During the application process, the Council agreed a revised description with the
appellants. I have used this more detailed revised description in the decision
paragraph in the interests of clarity.
Appeal Decision 6000394
2
Main Issue
4. The main issue of the appeal is the effect of the proposed development on the
character and appearance of the area.
Reasons for the Recommendation
5. Cranham Gardens features a variety of dwelling types, ranging in design, form and
materials. There are a mix of single storey and two-storey dwellings in the area and
a prevailing linear pattern with dwellings set back from front boundaries. Many
properties can be seen to have undergone alterations. 106 Cranham Gardens is a
large two-storey, detached dwelling with an attached garage and a generous
amount of garden space to the rear. It is situated between the detached bungalows
at 104 and 108 Cranham Gardens (Nos 104 and 108), both of which have single
storey rear extensions and back onto long rear gardens. These characteristics give
the area a mixed but cohesive suburban character.
6. The extensions would have a discreet presence in views from the street with the
mono pitched roof over the side extension retaining a single storey scale to this
side. To the rear, the width of the two storey element would match the existing
dwelling and its roof would have a complementary hipped profile. Its rear elevation
would be closely aligned with the rear extensions at Nos 104 and 108. Together
with the subservient appearance of the single storey rear extension, and their
matching facing materials, this would ensure a cohesive aesthetic. As a result, the
mass of the extensions would suitably blend with the host dwelling and would sit
comfortably within the generously proportioned rear garden setting.
7. The Havering Residential Extensions and Alterations Supplementary Planning
Document (2011) (SPD) confirms that the acceptable depth of any proposed rear
extension will also depend on a number of site-specific considerations. As the parts
of the side extension that would be visible from the street would closely reflect the
scale of the existing house and garage, and the two-storey rear extension has been
carefully designed to respond to its host, it would resonate with some of the key
aspects of the SPD. Therefore, any variance from other aspects of the design
guidance would not be harmful to the character and appearance of the area in this
instance.
8. I conclude, the proposal would have an acceptable effect on the character and
appearance of the area. In that regard, it would comply with the requirements in
Policies 7 and 26 of the London Borough of Havering Local Plan (2021) for
development to be of a high design quality and to respect, reinforce and
complement the local street scene.
Other Matters
9. Any deviance from the guidance in the SPD in terms of the recommended
measurements for extensions and a 45-degree line drawn from neighbouring
properties would not be harmful to neighbouring living conditions in this instance.
This is due to the position of the two-storey extension set away from the side
elevations of Nos 104 and 108 as well as the overall development not extending
significantly passed the rear elevations of these neighbouring dwellings.
Furthermore, given its single storey scale and mono-pitched roof, which would
reach its maximum ridge height away from the boundary, the side extension would
not result in any unacceptable overbearing or overshadowing effects to
Appeal Decision 6000394
3
neighbouring occupiers. There is no substantive evidence to demonstrate
otherwise and the Council has also not identified any detrimental impacts on the
living conditions of neighbouring occupiers. Overall, there would be no material
effects on outlook or light for neighbouring properties to either side of the appeal
site.
10. I note concerns expressed about access to neighbouring property for maintenance
and potential damage to buildings outside of the appellant's control during and post
development work. These are matters that would need to be resolved between the
parties involved and are not a reason to withhold the granting of planning
permission.
Conditions
11. In addition to the standard three-year period for implementation, it is necessary, in
the interest of certainty, to define the plans with which the development should
accord. To protect the character and appearance of the surrounding area and the
host dwelling, I am attaching a condition requiring materials used in the
construction of the external surfaces of the development to match those used in the
existing building. The council’s suggested condition, restricting the formation of any
windows or other opening in the flank walls, is also reasonable and necessary to
ensure suitable privacy for neighbouring occupiers is retained. However, I have
slightly amended the wording to this condition to relate to the extensions only as a
more stringent condition relating to the wider building would not be reasonable.
Conclusion and Recommendation
12. For the reasons given above and having had regard to all other matters raised, I
recommend that the appeal should be allowed.
E Nutman
APPEAL PLANNING OFFICER
Inspector’s Decision
13. I have considered all the submitted evidence and my representative’s report and on
that basis the appeal is allowed.
M Russell
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.