Construction of a rear slope roof dormer and side slope dormer along with the implementation of roof lights and solar panels to allow for a loft conversion
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Extensions
Heritage & Conservation
Character & Appearance
Inspector’s Reasoning
www.planningportal.gov.uk/planninginspectorate
p
Appeal Decision
Site visit made on 7 June 2023
by C J Leigh BSc(Hons) MPhil MRTPI
an Inspector appointed by the Secretary of State
Decision date:10 July 2023
Appeal Ref: APP/C5690/D/23/3320200
43 Penerley Road, London, SE6 2LH
• The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
• The appeal is made by Zulfiya Bradley against the decision of the Council of the London
Borough of Lewisham.
• The application Ref DC/22/128563, dated 23 September 2022, was refused by notice
dated 9 February 2023.
• The development proposed is construction of a rear slope roof dormer and side slope
dormer along with the implementation of roof lights and solar panels to allow for a loft
conversion.
Decision
1. The appeal is allowed and planning permission is granted for the construction
of a rear slope roof dormer and side slope dormer along with the
implementation of roof lights and solar panels to allow for a loft conversion at
43 Penerley Road, London, SE6 2LH in accordance with the terms of the
application ref DC/22/128563, dated 23 September 20222, subject to the
following conditions:
1) The development hereby permitted shall begin not later than three years
from the date of this decision.
1) Prior to commencement a detailed schedule and specification of all
external materials and finishes and windows roof coverings to be used on
the building shall be submitted to and approved in writing by the local
planning authority. The development shall be carried out in accordance
with the approved details.
2) The development hereby permitted shall be carried out in accordance
with the following approved plans: B.EX.01, B.EX.02, B.EX.2.1, B.EX.2.2,
B.EX.2.3, B.EX.2.4, B.EX.3.1, B.EX.3.2, B.EX.3.3, B.EX.3.4, B.EX.4.1,
B.EX.4.2, D.PR.0.1, D.PR.2.1, D.PR.2.2, D.PR.2.3, D.PR.2.4, D.PR.3.1,
D.PR.3.2, D.PR.3.3, D.PR.3.4, D.PR.4.1 & D.PR.4.2.
Reasons
2. The main issue in this appeal is the effect of the proposed development on the
character and appearance of the Culverley Green Conservation Area. Under s72
I have a duty under s72(1) of the Planning (Listed Buildings and Conservation
Areas) Act 1990 to pay special attention to the desirability of preserving or
enhancing the character or appearance of the Area.
Appeal Decision APP/C5690/D/23/3320200
2
3. The Conservation Area covers an area of substantial Edwardian residential
properties with a clear street plan, where the houses front the road in a regular
pattern. This gives a strong character of built development, with houses being
predominately of good quality red brick and steeply pitched roofs and gables,
and with trees and garden spaces contributing to the character. The
significance of the Area as a heritage asset derives from this regular street
plan, and the quality and form of the houses with good landscape character to
the roads.
4. The proposals would see alterations to the roof to provide a rear and a side
dormer, rooflights and PV panels. Policy HC1 of the London Plan 2021, Policies
15 and 16 of the Lewisham Core Strategy 2011, and DM Policies 30, 31 and 36
of the Lewisham Development Management Plan 2014 seek to ensure all
development is of a high standard of design that is compatible with the local
character of the area, and that conservation areas are preserved or enhanced.
The Council have also drawn my attention to the specific guidance for rear roof
extension in conservation areas contained in their Alterations and Extensions
Supplementary Planning Document 2019 (SPD). This requires such extensions
to be of exceptional design quality, high quality materials, to be set in
significantly from the eaves and sides, and to be no wider than two thirds of
the original roof.
5. The rear dormer in this appeal is shown to be set well-back from the eaves,
ridge and the party wall with No. 45. The dormer extends to adjoin the
projecting rear gable of the house which, in this instance, I consider
acceptable. It is clear to me from the SPD that rear dormers are not ruled out
in conservation areas, but rather the Council seeks to control their scale and
design; the overall scale of the dormer is not large, due to the set-backs noted
above and relative to the scale of the house, but if there was a gap retained
between the dormer and the projecting rear gable the dormer would have an
awkward relationship with the rest of the roof form due to a clash of the
dormer, gap area and the gable.
6. The design of the dormer sees traditional sliding sash windows, the centre of
which are positioned to align with the brick pillars beneath. Matching materials
are shown to be used, with zinc cladding, which would be suited to the existing
property. Thus, when combined with the points above, I consider the rear
dormer would be of a suitable siting, scale and design for the house and the
wider area.
7. A side dormer is proposed to the roof, to provide access to the converted loft
space. The SPD provides guidance on the circumstances in which side roof
extensions will be acceptable, and states that in most cases they will be
resisted in conservation areas. The proposal is of small scale, positioned behind
the chimney to the house and set well back on the roof slope away from the
front elevation looking towards the roof of the adjoining house of No. 41. These
matters mean there would be very limited visibility of the dormer from public
views, and in those views the dormer would be an appropriate design: it is
modest in scale, positioned above the first floor window below, with a pitched
roof that reflects the pitch of the host property and is set down from the
ridgeline.
8. I saw at my site visit there are a number of other properties in the area that
have side dormers. These vary in size and design, and I understand that some
Appeal Decision APP/C5690/D/23/3320200
3
of these pre-date the Council’s SPD. However, they do not impose upon what
constitutes the character and appearance of the Conservation Area, and I
consider the proposals in this appeal would also be an acceptable change to the
property. Hence, in this instance, I consider the side dormer to be an
appropriate addition.
9. The rooflights and the solar panels would be changes to the roof that are not
imposing upon the building or wider area, due to their limited visibility on the
roofs.
10. The proposed alterations and extensions to the property would thus be
appropriate to the house and the wider area. The significance of the heritage
asset would not be harmed, and hence on the main issue it is concluded the
character and appearance of the Conservation Area would be preserved. The
proposals would be consistent with the development plan policies and the SPD
referred to earlier.
11. The Council have suggested a number of conditions in the event of the appeal
being allowed, to which the appellant has raised no objection. I have attached
the suggested condition requiring the submission of details of materials to be
used, to ensure a satisfactory appearance to the development, and a condition
specifying the approved plans in the interest of precision.
C J Leigh
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.