Proposed ground floor and first floor rear extension
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Residential Amenity
Extensions
Character & Appearance
Inspector’s Reasoning
Appeal Decision
Site visit made on 25 March 2025
by J Davis BSc (Hons) MSc MRTPI
an Inspector appointed by the Secretary of State
Decision date: 3 April 2025
Appeal Ref: APP/F5540/D/24/3356270
22 Ivy Road, Hounslow, TW3 2DH
• The appeal is made under section 78 of the Town and Country Planning Act 1990 (as amended)
against a refusal to grant planning permission.
• The appeal is made by Mr Ajit Sachdeva against the decision of the Council of the London Borough
of Hounslow.
• The application Ref is P/2024/3147.
• The development proposed is described as ‘proposed ground floor and first floor rear extension’.
Decision
1. The appeal is dismissed.
Main Issues
2. The main issues are:
• the effect of the proposed development on the living conditions of the
occupiers of Nos 20 and 24 Ivy Road, with particular reference to light and
outlook; and
• the effect of the proposed development on the character and appearance of
the host dwelling and the surrounding area.
Reasons
Living conditions
3. The appeal property is a two storey, end of terrace dwelling located in row of
dwellings of a similar design and appearance. The dwelling has an existing single
storey rear extension of about 3m in depth.
4. The proposed proposal would result in a single storey extension projecting 6m
beyond the original two storey rear wall of the dwelling. My attention has been
drawn to the planning history of the site and in particular to a prior approval
application for a 6m deep extension. This application was refused by the Council
but was subsequently allowed on appeal1 with prior approval deemed to be granted
under Article 3(1) and Schedule 2, Part 1, Class A, of the Town and Country
Planning (General Permitted Development) (England) Order 2015 (as amended)
(GPDO).
1 Appeal Ref. APP/F5540/D/24/3341428
Appeal Decision APP/F5540/D/24/3356270
2
5. The proposed single storey extension would result in a ground floor of the same
dimensions overall as the single storey extension allowed on appeal. The Council’s
Residential Extensions Guidelines Supplementary Planning Document (2017)
(SPD) advises that single storey rear extensions to terraced dwellings should not
normally exceed 3.05m in depth to avoid loss of outlook and daylight to
neighbouring dwellings. Notwithstanding this, such guidance does not constitute a
rigid set of rules to be applied exclusively when other material considerations
indicate that an exception may be appropriate. Furthermore, the SPD guidance
does not reflect the permissible dimensions for extensions set out the GDPO.
6. The non-adjoining neighbour at 24 Ivy Road has a part two storey rear extension
close to the boundary with the appeal property. Whilst the proposed single storey
extension would extend beyond the rear elevation No 24, owing to its low height
and flat roof design, it would not result in any significant harm to the living
conditions of the occupiers of No 24. Furthermore, the first-floor rear extension
would not project significantly beyond the existing extension to No 24 and
accordingly, would not result in material harm to the neighbouring occupiers living
conditions in terms of loss of outlook or light. Whilst the Council raise concern
about a ground floor wc window on the flank elevation of the proposed extension,
no adverse overlooking would occur from this window due to the existing boundary
treatment.
7. The adjoining dwelling, 20 Ivy Road has not been extended to the rear. To the west
of No 20, 18 Ivy Road has a single storey extension on the boundary with No 20.
However No 20 benefits from a generous rear garden and a relatively open aspect
to the rear. Whilst the proposed single storey extension would be slightly higher
than the existing extension to the rear of the appeal property, I concur with the
previous appeal Inspector, that due to its height and flat roof design, the additional
single storey projection along the shared boundary would not result in a significant
loss of light or outlook to the occupiers of No 20.
8. The proposed first floor extension would have a flat roof design and would sit at
eaves height. However, notwithstanding its flat roof design, owing to the 3m depth
of the proposed first floor extension and its positioning on the boundary with No 20,
the two-storey flank wall would be visually imposing and overbearing when viewed
from the ground floor of No 20 and the part of the garden closest to the dwelling.
Moreover, the extension would be on the eastern side of No 20 and, in the absence
of any substantive evidence to the contrary, due to its depth and positioning on the
boundary, it would be likely to result in a reduction in natural light and sunlight to
the ground floor windows of No 20, at certain times of the day. The combination of
loss of outlook and loss of light would have a harmful effect on the living conditions
of the occupiers of No 20.
9. Therefore, the proposal would be contrary to Policies CC2 and SC7 of the London
Borough of Hounslow Local Plan 2015-2030 (2015) (LP) which together and
amongst other matters, seek to minimise harm to neighbouring residents by
avoiding an unacceptable loss of daylight/sunlight, outlook or by creating an
unacceptable sense of enclosure. It would also be contrary to the SPD which
advises that the depth of a first floor extension should not project more than 2.5m
beyond the rear wall of the house.
Appeal Decision APP/F5540/D/24/3356270
3
Character and appearance
10. Policies CC1 and CC2 of the LP expect proposals to respond to the context and
character of the area in terms of design. Policy SC7 of the LP requires
development proposals to complement the original building and for extensions to
have regard to the quality, character, materials and scale of the principal building,
be subordinate to the existing building and not overdevelop the site in terms of
mass and density. Guidance within the SPD advises that first floor extensions
should be proportionate and subordinate to the dimensions of the main house and
that the width of a first-floor rear extension should be no greater than half the width
of the original house.
11. The proposed single storey extension would represent a sizeable addition to the
dwelling but having regard to its low, flat roof design it would be proportionate and
subordinate to the host dwelling and would not significantly detract from its original
character and appearance. Moreover, the proposed extension would extend to the
same depth as the 6m deep extension allowed on appeal.
12. The flat roof design of the proposed first floor extension would help to reduce its
scale and bulk. I also acknowledge that it would be similar in design to the two
storey flat roof extension to the rear of 24 Ivy Road although that extension only
extends across part of the width of the dwelling. The proposed extension would
extend across the full width of the appeal property and this, in combination with its
depth of 3m, would result in an overly dominant, bulky addition.
13. I find that the proposed first floor extension by virtue of its width and depth would
fail to be subordinate to or well-integrated with the host dwelling. Accordingly, the
proposal would overwhelm and detract from the original character and appearance
of the dwelling. Whilst the extension would not be readily visible from any public
vantage points, it would, nonetheless, be a highly dominant addition which would
detract from the character and appearance of the existing rear garden environment.
14. I therefore conclude that the proposed first floor extension would have a harmful
effect on the character and appearance of the host dwelling and surrounding area.
Consequently, it would fail to comply with the design objectives of Policies CC1,
CC2 and SC7 of the LP and the SPD.
Other Matters
15. I acknowledge that the proposed extensions would be beneficial to the appellant
and would improve the family’s living space and living conditions. However, this
consideration does not outweigh the harm that I have identified above.
Conclusion
16. For the above reasons, and having regard to all other matters raised, I conclude
that the appeal should be dismissed.
J Davis
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.