Erection of a 4 meter deep single storey rear extension. Maximum height 3.4 meters, eaves height 2.5 meters
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Extensions
Fallback Position
Inspector’s Reasoning
Appeal Decision
Site visit made on 13 November 2024
by Hannah Ellison BSc (Hons) MSc MRTPI
an Inspector appointed by the Secretary of State
Decision date: 3rd December 2024
Appeal Ref: APP/P4605/D/24/3347655
14 Oakmeadow Close, Shard End, Birmingham B33 0AQ
• The appeal is made under section 78 of the Town and Country Planning Act 1990 (as
amended) against a refusal to grant approval required under Article 3(1) and Schedule
2, Part 1, Class A of the Town and Country Planning (General Permitted Development)
(England) Order 2015 (as amended).
• The appeal is made by Mr Stefan Miron against the decision of Birmingham City Council.
• The application Ref is 2024/03428/PA.
• The development proposed is the erection of a 4 meter deep single storey rear
extension. Maximum height 3.4 meters, eaves height 2.5 meters.
Decision
1. The appeal is dismissed.
Preliminary Matters
2. During the appeal the appellant indicated a new drawing would be provided.
However, it is important that I consider this appeal based on the plans which
were before the Council and on which it made its decision. I have proceeded
accordingly.
3. For the avoidance of doubt the description of development above is taken from
the decision notice and appeal form as this is the most accurate version
provided.
Main Issue
4. The main issue is whether the proposal constitutes permitted development.
Reasons
5. Under Article 3(1) and Schedule 2, Part 1, Class A of the Town and Country
Planning (General Permitted Development) (England) Order 2015 (as
amended) (the GPDO), planning permission is granted for the enlargement of
a dwellinghouse subject to limitations and conditions.
6. The proposed extension would exceed the limits in paragraph A.1(f) in respect
of its projection beyond the rear wall of the original dwellinghouse, however it
would fall within the limit in paragraph A.1(g). As such, an application was
made to the Council for prior approval.
7. However, the Council’s concerns in this case appear to centre on whether the
proposal meets the limitations in paragraph A.1(j), which states that
development is not permitted if the enlarged part of the dwellinghouse would
extend beyond a wall forming a side elevation of the original dwellinghouse,
and would (i) exceed 4 metres in height, (ii) have more than a single storey,
or (iii) have a width greater than half the width of the original dwellinghouse.
Appeal Decision APP/P4605/D/24/3347655
2
8. Paragraph A.1(ja) goes on to state that any total enlargement (being the
enlarged part together with any existing enlargement of the original
dwellinghouse to which it will be joined) exceeds or would exceed the limits
set out in sub-paragraphs (e) to (j).
9. The appeal property is a two-storey end of terrace dwelling which appears to
have non-original side and rear extensions. In accordance with paragraph
A.1(ja), as the proposed extension would be joined to the previous
enlargements which are positioned to the side and rear of the host property,
the size of the total enlargement would have a width greater than half the
width of the original dwellinghouse, thus it would exceed the limit set out in
A.1(j)(iii).
10. Accordingly, the proposal does not constitute permitted development.
Conclusion
11. The proposal is not permitted development under Article 3(1) and Schedule 2,
Part 1, Class A of the GPDO as applied for, thus the appeal should be
dismissed.
H Ellison
INSPECTOR