6 metre rear extension

📊

See the success rate & inspector analytics

Free to view — just create an account, no payment needed.

Sign Up Free

Technical Issues Heatmap

Fallback Position
Extensions

Inspector’s Reasoning

Appeal Decision Site visit made on 29 May 2019 by Grahame Gould BA MPhil MRTPI an Inspector appointed by the Secretary of State Decision date: 13 June 2019 Appeal Ref: APP/G5750/D/19/3227499 307 Dersingham Avenue, London E12 6HP • The appeal is made under section 78 of the Town and Country Planning Act 1990 against a refusal to grant approval required under Article 3(1) and Schedule 2, Part 1, Class A, Paragraph A.4 of the Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). • The appeal is made by Mr Brian Beaupierre against the decision of the Council of the London Borough of Newham. • The application Ref 19/00774/PREHH, dated 10 March 2019, was refused by notice dated 16 April 2019. • The development proposed is described as ‘6 metre rear extension’. Decision 1. The appeal is dismissed. Main Issue 2. The main issue is whether the proposed development complies with the conditions, limitations or restrictions applicable to permitted development. Reasons 3. The application for prior approval was made under Schedule 2, Part 1, Class A of the Town and Country Planning (General Permitted Development) (England) Order 2015, as amended (the Order) and would, as described on the application form, involve the construction of a 6.0 metre deep rear extension to 307 Dersingham Avenue (No 307), a mid terrace dwellinghouse. The proposed development would have two limbs, with there being a 100mm gap between the inner elevations of each of the limbs1 and the development’s layout would be akin to a two pronged fork. 4. While there would be a small gap between the two limbs of the development, I consider that it should be considered as being a single extension to No 307. That is because each limb of the development would open directly onto what would become a single open plan area to the rear of the existing property and it would seem very unlikely that both limbs would not be built at the same time, given how close their inner elevations would be with one another. 5. Under Schedule 2, Part 1, Class A of the Order certain enlargements (extensions) of a dwellinghouse will benefit from permitted development rights for their construction provided all of the limitations stated in Class A.1 are met. For extensions exceeding the limitations stated in paragraph A.1(f) 1 As dimensioned on drawing 307 PA 01 and referred to in the appellant’s grounds of appeal Appeal Decision APP/G5750/D/19/3227499 2 and coming within the scope of limitations stated in paragraph A.1(g) there is a conditional requirement (A.4) for an application to be made to the relevant local planning authority for its prior approval for the development or a determination as to whether such approval is required. 6. The Council refused to grant its prior approval for the development under condition A.4(3) because it contends that limitation A.1(j)(iii) of the Order would not be met. Limitation A.1(j)(iii) states development is not permitted by Class A if ‘… the enlarged part of the dwellinghouse would extend beyond a wall forming a side elevation of the original dwellinghouse, and would – … (iii) have a width greater than half the width of the original dwellinghouse …’. 7. No 307 has a single storey rear projection, which appears to have been extended at some stage, given it is of different proportions to the originally constructed and surviving projections of the other houses in this terrace. For the purposes of limitation A.1(j) the side wall of that projection is a ‘side elevation’. The extension subject to the prior approval application would occupy the space between the rear projection’s side elevation and the boundary that No 307 shares with No 305 and the application drawing shows that its width would be greater than half that of the original dwellinghouse, irrespective of whether the rear projection’s width is as originally constructed or has been increased as part of a previous extension. I therefore consider that the proposed extension’s width would mean that it would not comply with limitation A.1(j)(iii). 8. Even if I am incorrect in believing that the development should be treated as being a single extension, the width of the northern limb of the development alone would be greater than half the width of the original dwellinghouse and would therefore not comply with limitation A.1(j)(iii). That would mean that not all of the limitations stated in Class A.1 of the Order would be met. 9. Given that I have found at the very least that the northern limb of the development would not comply with limitation A.1(j)(iii), I consider, irrespective of whether the southern limb of the development would or would not comply with limitation A.1(ja), the development as a whole would not meet all of the limitations stated in Class A.1. Conclusion 10. For the reasons given above, I conclude that the proposed development would not comply with the conditions, limitations or restrictions applicable to permitted development and that the appeal should be dismissed. Grahame Gould INSPECTOR
Expert Representation

Don't leave your appeal to chance.

Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.

Get Free Review How it works →