6 metre rear extension
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Fallback Position
Extensions
Inspector’s Reasoning
Appeal Decision
Site visit made on 29 May 2019
by Grahame Gould BA MPhil MRTPI
an Inspector appointed by the Secretary of State
Decision date: 13 June 2019
Appeal Ref: APP/G5750/D/19/3227499
307 Dersingham Avenue, London E12 6HP
• The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant approval required under Article 3(1) and Schedule 2, Part 1,
Class A, Paragraph A.4 of the Town and Country Planning (General Permitted
Development) (England) Order 2015 (as amended).
• The appeal is made by Mr Brian Beaupierre against the decision of the Council of the
London Borough of Newham.
• The application Ref 19/00774/PREHH, dated 10 March 2019, was refused by notice
dated 16 April 2019.
• The development proposed is described as ‘6 metre rear extension’.
Decision
1. The appeal is dismissed.
Main Issue
2. The main issue is whether the proposed development complies with the
conditions, limitations or restrictions applicable to permitted development.
Reasons
3. The application for prior approval was made under Schedule 2, Part 1, Class A
of the Town and Country Planning (General Permitted Development)
(England) Order 2015, as amended (the Order) and would, as described on
the application form, involve the construction of a 6.0 metre deep rear
extension to 307 Dersingham Avenue (No 307), a mid terrace dwellinghouse.
The proposed development would have two limbs, with there being a 100mm
gap between the inner elevations of each of the limbs1 and the development’s
layout would be akin to a two pronged fork.
4. While there would be a small gap between the two limbs of the development,
I consider that it should be considered as being a single extension to No 307.
That is because each limb of the development would open directly onto what
would become a single open plan area to the rear of the existing property and
it would seem very unlikely that both limbs would not be built at the same
time, given how close their inner elevations would be with one another.
5. Under Schedule 2, Part 1, Class A of the Order certain enlargements
(extensions) of a dwellinghouse will benefit from permitted development
rights for their construction provided all of the limitations stated in Class A.1
are met. For extensions exceeding the limitations stated in paragraph A.1(f)
1 As dimensioned on drawing 307 PA 01 and referred to in the appellant’s grounds of appeal
Appeal Decision APP/G5750/D/19/3227499
2
and coming within the scope of limitations stated in paragraph A.1(g) there is
a conditional requirement (A.4) for an application to be made to the relevant
local planning authority for its prior approval for the development or a
determination as to whether such approval is required.
6. The Council refused to grant its prior approval for the development under
condition A.4(3) because it contends that limitation A.1(j)(iii) of the Order
would not be met. Limitation A.1(j)(iii) states development is not permitted
by Class A if ‘… the enlarged part of the dwellinghouse would extend beyond a
wall forming a side elevation of the original dwellinghouse, and would – … (iii)
have a width greater than half the width of the original dwellinghouse …’.
7. No 307 has a single storey rear projection, which appears to have been
extended at some stage, given it is of different proportions to the originally
constructed and surviving projections of the other houses in this terrace. For
the purposes of limitation A.1(j) the side wall of that projection is a ‘side
elevation’. The extension subject to the prior approval application would
occupy the space between the rear projection’s side elevation and the
boundary that No 307 shares with No 305 and the application drawing shows
that its width would be greater than half that of the original dwellinghouse,
irrespective of whether the rear projection’s width is as originally constructed
or has been increased as part of a previous extension. I therefore consider
that the proposed extension’s width would mean that it would not comply with
limitation A.1(j)(iii).
8. Even if I am incorrect in believing that the development should be treated as
being a single extension, the width of the northern limb of the development
alone would be greater than half the width of the original dwellinghouse and
would therefore not comply with limitation A.1(j)(iii). That would mean that
not all of the limitations stated in Class A.1 of the Order would be met.
9. Given that I have found at the very least that the northern limb of the
development would not comply with limitation A.1(j)(iii), I consider,
irrespective of whether the southern limb of the development would or would
not comply with limitation A.1(ja), the development as a whole would not
meet all of the limitations stated in Class A.1.
Conclusion
10. For the reasons given above, I conclude that the proposed development would
not comply with the conditions, limitations or restrictions applicable to
permitted development and that the appeal should be dismissed.
Grahame Gould
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.