Demolition of single storey rear projections and construction of 4.3 metre single storey rear extension

📊

See the success rate & inspector analytics

Free to view — just create an account, no payment needed.

Sign Up Free

Technical Issues Heatmap

Residential Amenity
Fallback Position
Extensions

Inspector’s Reasoning

Appeal Decisions Site visit made on 20 February 2019 by A McCormack BSc (Hons) MRTPI an Inspector appointed by the Secretary of State Decision date: 13th March 2019 Appeal A: Ref: APP/M5450/D/19/3220122 103 Welldon Crescent, Harrow HA1QW • The appeal is made under section 78 of the Town and Country Planning Act 1990 against a refusal to grant approval required under Schedule 2, Part 1, Class A of the Town and Country Planning (General Permitted Development) Order 2015, as amended (the GPDO). • The appeal is made by Mr Seyer Nomoni against the decision of the Council of the London Borough of Harrow. • The application Ref P/5029/18/PRIOR, dated 14 November 2018, was refused by notice dated 24 December 2018. • The development proposed is demolition of single storey rear projections and construction of 4.3 metre single storey rear extension. Appeal B: Ref: APP/M5450/D/19/3220126 103 Welldon Crescent, Harrow HA1QW • The appeal is made under section 78 of the Town and Country Planning Act 1990 against a refusal to grant approval required under Schedule 2, Part 1, Class A of the Town and Country Planning (General Permitted Development) Order 2015, as amended (the GPDO). • The appeal is made by Mr Seyer Nomoni against the decision of the Council of the London Borough of Harrow. • The application Ref P/5033/18/PRIOR, dated 14 November 2018, was refused by notice dated 24 December 2018. • The development proposed is demolition of single storey rear projection and construction of single storey rear extension. Decision 1. Appeal A is dismissed and Appeal B is dismissed. Procedural Matters and Background 2. As set out above, there are two appeals on this site. They differ in relation to the extent and design of the proposed single storey rear extensions. In Appeal A, the extension is proposed to a depth of 4.3 metres from the rear elevation of the host property. In Appeal B, the proposed extension would be to a depth of 5.8 metres from the rear elevation. I have considered each case on its individual merits. However, to avoid duplication, I have dealt with the two schemes together except where otherwise stated. 3. Schedule 2, Part 1, Class A and limitation A.1(g) of the GPDO provides for extensions to single family dwellings up to 6 metres deep from the original rear elevation for semi-detached/terraced houses, such as in these appeal cases. Such provision is subject to Condition A.4 of the GPDO which requires a prior approval Appeal Decisions APP/M5450/D/19/3220122, APP/M5450/D/19/3220122 2 procedure to be undertaken which includes consultation with adjoining property owners or occupiers. In the event any objections are received from neighbouring residents the prior approval for the development is required from the local planning authority. Condition A.4(9) requires that the Council, as the local planning authority, must consider the impact of the proposal on the amenity of all adjoining premises and existing site circumstances. 4. The prior approval procedure is not considered as a substitute for a Certificate of Lawfulness. Therefore, no overall assessment of the lawfulness of both appeal proposals has been made. Nonetheless, during my visit to the site, it was noted the neighbouring property at 101 Welldon Crescent (No.101) has windows and doors in its rear elevation in close proximity to the boundary with the appeal property. It is also noted the garden of No.101 is characterised as being narrower than either of its neighbours. Main Issue 5. Having considered the above, the main issue in both Appeals is the effect of the proposed development on the living conditions of the neighbouring occupiers of 101 Welldon Crescent with particular regard to outlook. Reasons 6. The pattern of development in the locality results in the appeal property being at an angle to its adjoining neighbouring property at No.101. This causes the rear elevations of the properties, and the boundary between them, not being aligned in the usual way. In addition, I note the rear elevation of the appeal property is set back about one metre from the rear elevation of No.101. 7. The Council’s Residential Design Guide Supplementary Planning Document 2010 (the RDG) makes allowance for a three-metre depth running adjacent to the boundary of an adjoining semi-detached dwelling. Given the specific site circumstances, I note the proposal in Appeal A, which indicates an extension depth of 4.3 metres, would result in a development which would create a visible flank wall approximately 3.5 metres long adjacent to the boundary with No.101. This would be significantly greater than the allowance set out in the RDG. Due to the proximity of the ground floor rear windows of No.101 to the appeal property and boundary, this would result in a significant adverse visual impact on the outlook of the occupiers of No.101. Moreover, this impact on outlook for neighbouring occupiers would be exacerbated by the acute angle of the boundary between the two properties in relation to the rear elevation of No.101. 8. The proposed extension within Appeal B would result in a greater depth from the rear elevation of the appeal property to 5.8 metres. However, the additional 1.5 metres would be set back from the boundary with No.101. As a result, the impact of this additional element on the outlook of the occupiers of No.101 would be limited. Therefore, I find the impact of the Appeal B scheme in relation to outlook from the rear of No.101 would be similar to the Appeal A proposal. In both cases, I find the adverse impact on the outlook of neighbouring occupiers would be significant and would be far greater than allowed for in the RDG. 9. From the submitted evidence, I note the angle between the neighbouring properties at Nos.101 and 103 is not reflected on the existing and proposed plans for both appeals submitted by the appellant. As a result, the impact of the proposed flank walls in each case along the boundary on No.101 are not correctly demonstrated. From my observations during the site visit, it was evident such proposals, whilst just 0.5 metres longer along the boundary than the RDG provides for, would lead to the significant diminishing of outlook and general residential Appeal Decisions APP/M5450/D/19/3220122, APP/M5450/D/19/3220122 3 amenity for the occupiers of No.101. The site visit also confirmed my concerns about the intrusive and overly dominant nature of the flank wall of the proposals in both Appeal A and Appeal B on the neighbouring property and its occupiers. 10. Although it is said that there is a good amount of screening between the properties, with some trees considerably taller than the proposed height of the two extensions in Appeal A and Appeal B, it is the case that some trees on the appeal property side of the boundary would need to be removed to construct either of the proposed developments. Therefore, whilst I have considered these matters carefully, I do not agree that the visibility of the proposed extensions would be significantly reduced by the amount of existing or retained screening. 11. I have taken particular note of the appellant’s points regarding the intentions of the GPDO in relation to allowing householders to be able to build larger single- storey rear extensions under permitted development rights. I have also had regard to the arguments and reasons as to why the appellant states that both proposals set out in Appeal A and Appeal B would not project significantly beyond the rear elevation of the neighbouring property at No.101 and would not significantly reduce the outlook for its occupiers. However, from what I have seen and read and taking into consideration the site circumstances, including the narrowness of the rear garden of No.101 and the angular relationship between the appeal property and its neighbouring dwelling, I find both schemes within Appeal A and Appeal B would be significantly harmful to the outlook and general residential amenity of the occupiers at No.101. 12. As a result, I find these matters raised by the appellant not to be of such significance as to outweigh the harm I have identified and the resultant conflict with the relevant policies of the development plan. 13. Consequently, I conclude that both of the proposed developments set out within Appeal A and Appeal B would result in significant detrimental harm to the living conditions of the neighbouring occupiers of 101 Welldon Crescent with particular regard to outlook. Therefore, both proposals would be contrary to Policy DM1 of the Development Management Policies Local Plan 2013 and the relevant provisions of the Harrow RDG. Conclusion 14. Therefore, for the above reasons, and having had due regard to all other matters raised, I conclude that both Appeal A and Appeal B should be dismissed. Andrew McCormack INSPECTOR
Expert Representation

Don't leave your appeal to chance.

Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.

Get Free Review How it works →