First floor rear extension

📊

See the success rate & inspector analytics

Free to view — just create an account, no payment needed.

Sign Up Free

Technical Issues Heatmap

Residential Amenity
Extensions

Inspector’s Reasoning

www.planningportal.gov.uk/planninginspectorate Appeal Decision Site visit made on 14 January 2019 by P Eggleton BSc(Hons) MRTPI an Inspector appointed by the Secretary of State Decision date: 22 January 2019 Appeal Ref: APP/M0655/D/18/3211522 12 Higher Lane, Lymm, Warrington WA13 0AP  The appeal is made under section 78 of the Town and Country Planning Act 1990 against a refusal to grant planning permission.  The appeal is made by Mrs E Scales against the decision of Warrington Borough Council.  The application Ref 2018/32481, dated 20 March 2018, was refused by notice dated 21 June 2018.  The development proposed is a first floor rear extension. Decision 1. The appeal is dismissed. Main Issue 2. The main issue is the effect on the living conditions of the residents of 10 Higher Lane with regard to outlook and light. Reasons 3. The proposed extension would be built close to the rear facing bedroom dormer window within the neighbouring property. This is the only window to this habitable room. A dormer window generally has a more limited outlook as a result of its design. The position of this window within the room, would ensure that the proposal would not be discernible when in much of the more internal areas of the neighbouring bedroom. 4. When in the part of the bedroom near to the rear of the house, the window relies on an outlook directly to the rear and diagonally towards the proposed works. Despite the relative height of the window and the slope of the proposed roof, the new works would be a dominant feature when in the rear of the neighbouring bedroom. The setback of the extension from the shared boundary and its limited depth and height would limit this impact. However, I am not satisfied that the setback proposed would be sufficient to retain a satisfactory outlook. The roof of the extension would be an unacceptably overbearing addition when in part of the neighbouring bedroom. 5. With regard to light, the bedroom has a southerly aspect and light levels overall would not be unacceptably changed. Direct sunlight would be reduced, for short periods, during the mornings of the winter months. This adds to my concern with regard to outlook. Appeal Decision APP/M0655/D/18/3211522 2 6. With regard to the roof light in the kitchen, given the aspect of the property and the secondary nature of the window, although some direct sunlight may be lost for short periods during the winter months, this limited change would not be unacceptable. 7. Concern has been raised with regard to overlooking from the proposed bedroom window. Views would be possible to the rear part of the neighbouring garden. The size of the window and the layout of the room, increase this potential. However, given the angle of views, the limited area that would be overlooked and the nature of that part of the neighbouring garden, I am not satisfied that this reduction of privacy would unacceptably harm the living conditions of the neighbouring residents. 8. Overall, I conclude that the proposal, due to its limited setback from the shared boundary and the neighbouring bedroom window, would result in unacceptable harm to the living conditions of the residents of 10 Higher Lane due to the reduction in outlook. The limited loss of direct sunlight would add to this concern. The proposal would be contrary to Policy QE 6 of the Warrington Local Plan Core Strategy 2014 which seeks to protect neighbouring amenity. As the policy generally accords with the amenity requirements of the National Planning Policy Framework 2018, I afford it considerable weight. 9. The Council’s Supplementary Planning Guidance: House Extensions suggests that an extension should not extend beyond a 45 degree line from the neighbouring bedroom window. This should be drawn from the middle of the window along a horizontal plane. This proposal conflicts with this guidance but it appears that the code relates to full height extensions and does not appear to anticipate lower roof heights such as those that would exist with this proposed design. It would appear that the highest part of the extension would not conflict with the code but there would be conflict with parts of the roof that would be relatively high in relation to the residents within the neighbouring property. I am not satisfied that full conflict with the guidance would result but this does not suggest that a different conclusion with regard to Policy QE 6 should be reached. 10. I note the lack of objection from the Parish Council and I have considered the matters put forward in support of the proposal. The particular circumstances of the appellant’s family weigh in favour of the proposal but as a similar but smaller extension, set further from the shared boundary, would provide a reasonable sized bedroom with a reduced impact, the weight I afford this matter is reduced. I conclude that the considerations in favour of the proposal are not sufficient to outweigh my concerns with regard to the living conditions of the residents of 10 Higher Lane. I therefore dismiss the appeal. Peter Eggleton INSPECTOR
Expert Representation

Don't leave your appeal to chance.

Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.

Get Free Review How it works →