Demolition of existing garage, utility, lounge extension and outbuilding. Construction of new side and rear part one and part two storey extension
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Green Belt Policy
Extensions
Rural Impact
Inspector’s Reasoning
Appeal Decision
Site visit made on 28 June 2022 by Darren Ellis MPlan
Decision by John Morrison BA (Hons) MSc MRTPI
an Inspector appointed by the Secretary of State
Decision date: 30th November 2022
Appeal Ref: APP/R0660/D/22/3294865
Acresfield, Carr Lane, Alderley Edge SK9 7SL
• The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
• The appeal is made by Mrs J Hyland against the decision of Cheshire East Borough
Council.
• The application Ref 21/4468M, dated 20 August 2021, was refused by notice dated
1 March 2022.
• The development proposed is described as ‘demolition of existing garage, utility, lounge
extension and outbuilding. Construction of new side and rear part one and part two
storey extension.’
Decision
1. The appeal is dismissed.
Appeal Procedure
2. The site visit was undertaken by an Appeal Planning Officer whose
recommendation is set out below and to which the Inspector has had regard
before deciding the appeal.
Main Issues
3. The main issues are:
• Whether the proposal would be inappropriate development in the Green
Belt;
• The effect of the proposal on the openness of the Green Belt; and
• If the proposal is inappropriate development, whether the harm by
reason of inappropriateness, and any other harm, is clearly outweighed
by other considerations, so as to amount to the very special
circumstances necessary to justify it.
Reasons for the Recommendation
4. The National Planning Policy Framework (the Framework) establishes that new
buildings in the Green Belt are inappropriate except in certain circumstances,
including where they involve the extension of an existing building. This is
provided that the extension does not result in a disproportionate addition over
and above the size of the original building. The Framework defines ‘original
building’ as ‘a building as it existed on 1 July 1948, or, if constructed after 1
Appeal Decision APP/R0660/D/22/3294865
2
July 1948, as it was built originally.’ It does not however define
‘disproportionate’.
5. Policies PG3 of the Cheshire East Local Plan Strategy (July 2017) (CELPS) is
consistent with the Framework in that it seeks to protect the Green Belt but
allows limited extensions to existing dwellings. Policy GC12 of the Macclesfield
Borough Local Plan (January 2004) (MBLP) states that alterations and
extensions to existing houses in the countryside may be granted for up to 30%
providing the scale and appearance of the house is not significantly altered.
The policy further states that an exception to this threshold may be permitted
where the proposal lies within a group of houses or ribbon development where
the extension would not be prominent.
6. Given the absence of a definition within the Framework, it is common for
guidelines and policies to be set within Local Plans to reflect local
circumstances. Such local criteria will often specify volumetric or floorspace
limits but may also set out site specific circumstances where exceptions may
apply. Therefore, and notwithstanding the age of the MBLP, I am satisfied that
the criteria within Policy GC12 remain broadly consistent with the Framework
and mark a reasonable method to assist in making a judgement as to whether
an extension would be ‘disproportionate’.
7. The main parties agree that the removal of the existing extensions and the
construction of a new part two and part single storey extension would result in
an increase of 46% of the floorspace of the original dwelling. This would
significantly exceed the 30% threshold set out in Policy GC12.
8. While the proposed two-storey side extension has been designed to be
subservient to the main dwelling, it would nevertheless add considerable bulk
and massing and would be highly visible from public vantage points. As such,
the two-storey side extension would significantly increase the prominence of
the dwelling, failing to meet the exception for extensions to houses in the
countryside.
9. My attention has been drawn to a previous appeal at 3 Carr Lane, where a first
floor extension above an existing garage was allowed1. In that case the
Inspector concluded that there would be no harm to the Green Belt as the
footprint of the building would be unchanged. This is not the case in the appeal
before me. This appeal does not therefore change my findings in regard to the
appeal scheme’s inappropriateness.
10. Consequently, given the bulk and massing of the proposed extension and as
the proposal would significantly exceed the 30% threshold, the proposal would
represent a disproportionate addition and therefore would be inappropriate
development within the Green Belt. For these reasons, the proposal would
conflict with Paragraph 149 of the Framework, Policy PG3 of the CELPS and
Policy GC12 of the MBLP. Together, these policies seek to protect the Green
Belt from harmful development.
Openness of the Green Belt
11. Openness is an essential characteristic of the Green Belt. The Planning Practice
Guidance states that openness is capable of having both spatial and visual
aspects, so that both the visual impact of the proposal and its volume may be
1 Appeal ref. APP/C0630/A/04/1138662
Appeal Decision APP/R0660/D/22/3294865
3
relevant.2 Whilst the existing built development would create something of a
backdrop to the proposal and planting may reduce its obviousness, the overall
scale, bulk and mass of the extension would still result in harm to the visual
and spatial aspects of the Green Belt’s openness, unavoidably reducing it. This
harm would be as well that caused by the proposal’s inappropriateness.
Other Considerations
12. The existing dwelling is of a simple design, and the current single-storey
extension is finished in brick to match the main dwelling. The submitted
drawings show the current extension as having a flat roof, however at the time
of my site visit the extension had a pitched roof that is in keeping with the
existing dwelling, although the roof of the extension was missing the tiles. The
Council do not object to the design of the appeal scheme, and I have no reason
to disagree, but this would be a lack of harm and thus a neutral consideration.
13. I understand that Certificates of Lawful Development have recently been issued
for separate single-storey and two-storey rear extensions, and that these
extensions would increase the floorspace of the property by more than the
appeal proposal. While these extensions would have a greater spatial impact
than the appeal proposal, owing to their position mostly behind the existing
building, they would have a considerably smaller visual effect on the Green
Belt’s openness than the appeal proposal. In addition, a scheme for permitted
development, should it be considered as such, does not fall to be assessed in
regard to its Green Belt effects as is the case with the appeal proposal. In any
case, and for the above reasons, the permitted development extensions would
not cause any greater harm to the Green Belt than the appeal proposal.
Whether Very Special Circumstances Exist
14. The proposed extension would cause harm to the Green Belt by way of
inappropriateness and in reducing its openness, to which I afford substantial
weight as per paragraph 148 of the Framework. Development should not be
approved unless the harm to the Green Belt, and any other harm, is clearly
outweighed by other considerations. The other considerations identified above
would have a neutral effect and consequently do not clearly outweigh the
totality of the harm. The very special circumstances necessary to justify the
proposal do not therefore exist.
Conclusion and Recommendation
15. There are no material considerations worthy of sufficient weight which would
indicate that a decision should be made other than in accordance with the
development plan. Therefore, for the reasons given above, I recommend that
the appeal be dismissed.
Darren Ellis
APPEAL PLANNING OFFICER
2 Planning Practice Guidance, Paragraph: 001 Reference ID: 64-001-20190722
Appeal Decision APP/R0660/D/22/3294865
4
Inspector’s Decision
16. I have considered all the submitted evidence and the Appeal Planning Officer’s
report, and I agree with the recommendation that the appeal should be
dismissed.
John Morrison
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.