For a single storey rear extension to dwellinghouse
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Extensions
Inspector’s Reasoning
Appeal Decision
Site visit made on 12 April 2022
by Mr S Rennie BSc (Hons), BA (Hons), MA, MRTPI
an Inspector appointed by the Secretary of State
Decision date: 3 May 2022
Appeal Ref: APP/T5150/D/21/3284577
88 Brampton Road, LONDON, NW9 9DD
• The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant approval required under Schedule 2, Part 1, Class A of the
Town and Country Planning (General Permitted Development) (England) Order 2015 (as
amended).
• The appeal is made by Mr Sanjay Kerai against the decision of London Borough of
Brent.
• The application Ref 21/2166, dated 9 June 2021, was refused by notice dated 19 July
2021.
• The development proposed is for a single storey rear extension to dwellinghouse.
Decision
1. The appeal is dismissed.
Preliminary Matters
2. Under Article 3(1) and Schedule 2, Part 1, Class A of the General Permitted
Development Order (GPDO), planning permission is granted for the
enlargement of a dwellinghouse subject to limitations and conditions.
Main Issue
3. The main issue is whether the proposed development would constitute
permitted development under the terms of Schedule 2, Part 1, Class A.1 (g) of
the GDPO.
Reasons
4. The Council state that the proposed enlarged part of the dwelling would extend
beyond the rear wall by more than 6m. Both the application form and the
submitted plans indicate 6m deep extensions, though the proposed extensions
are angled to follow the line of the rear garden boundaries.
5. It is this angled form which results in a straight-line distance (not angled) from
the rear wall of the office/study to the furthest extent of the proposed
extension of greater than 6m. Whilst the submitted plan shows angled lines of
6m to follow the side elevation boundaries of the proposed extensions, the
permitted development criteria does not allow for this, with it simply stating
that it is permitted to extend beyond the rear wall of the original dwellinghouse
by more than 8 metres in the case of a detached dwellinghouse, or 6 metres in
the case of any other dwellinghouse. This is a terraced house and there would
be a distance of over 6m from an original rear elevation to the end of part of
the proposed extensions.
Appeal Decision APP/T5150/D/21/3284577
2
6. Further to the above, the angled extension proposed from the rear of the
dwelling means that it would also project out from the line of the original side
of the dwelling. Under Class A, paragraph J of the GPDO states that if the
enlarged part of the dwellinghouse would extend beyond a wall forming a side
elevation of the original dwellinghouse it would have to have a width not
greater than half the width of the original dwellinghouse. The proposed
extension spans much of the width of the dwelling (over half) and so does not
comply with this criterion.
7. On the basis of the evidence before me and my observations at the site visit,
the proposed development would not satisfy the criteria to be permitted
development, under the terms of Schedule 2, Part 1, Class A.1 of the GPDO.
Other Matters
8. Since I do not conclude that the proposal would be permitted development, it is
not necessary to consider the effect it would have on the amenity of the
neighbouring occupiers in this case.
9. To note, this conclusion does not infer any opinion on the outcome of any
future planning application that the appellant may now want to submit for the
extension as proposed, now I have resolved that it is not permitted
development.
Conclusion
10. For the reasons given above I conclude that the appeal should be dismissed.
Mr S Rennie
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.