Outrigger roof extension
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Extensions
Character & Appearance
Policy Weight
Inspector’s Reasoning
Appeal Decision
Site visit made on 22 April 2021
by Sarah Colebourne MA, MRTPI
an Inspector appointed by the Secretary of State
Decision date: 19 May 2021
Appeal Ref: APP/T5150/D/20/3263007
40 Langler Road, London, NW10 5TL
• The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
• The appeal is made by Holly and Jake Lofdahl against the decision of the Council of the
London Borough of Brent.
• The application Ref 20/2169, dated 21 July 2020, was refused by notice dated 2
October 2020.
• The development proposed is described as an ‘outrigger roof extension.’
Decision
1. The appeal is dismissed.
Preliminary matter
2. The Council’s decision describes the proposal as ‘proposed outrigger roof
extension works including erection of single storey side extension; replacement
of windows to front and rear projections; replacement of door at rear and
replacement of existing side boundary fence and gate to dwellinghouse’ and as
this describes the proposal in more detail I have used this as the basis for my
decision.
3. Most of the works applied for under this application have already been
approved under a recent planning permission (20/0992) and Lawful
Development Certificate (20/1479) which are extant permissions. The Council
has not objected to those parts of the proposal and from what I have seen, I
have no reason to disagree. I have therefore considered only the proposed
roof extension over the outrigger in this appeal.
Reasons
4. The main issue in this appeal is the effect of the proposed development on the
character and appearance of the dwelling and the area. The development plan
includes policy DMP1 in the Council’s Development Management Policies
document which, amongst other things, seeks to ensure that proposals are of a
scale and design that complements the locality.
5. The appeal site comprises an end terrace Victorian house in a residential street
of similar properties. Whilst some properties have been extended to the rear,
in general the dwellings retain their original form of a main building with a
subservient outrigger which contributes to the attractive period character of the
area.
Appeal Decision APP/T5150/D/20/3263007
2
6. The proposed roof extension would extend across some 3m of the outrigger
with a height of some 2.9m and no set back from the eaves. Together with the
approved loft conversion and rear dormer it would create an L-shaped dormer.
Its siting would be contrary to the Council’s guidance in its SPD2 Residential
Extensions Design Guide (2018) which states that dormers that extend onto a
rear projection will not normally be permitted.
7. I saw at my visit that the neighbouring property at no 42 has a similar L-
shaped dormer but the Council has no planning history for that and from what I
saw it does not make a positive contribution to the area and does not therefore
set a precedent for this proposal. Whilst I noted rear dormers at other
properties in the street, I was unable to see any other comparable examples
from the site and the Council says that there is only one other example in this
terrace of ten dwellings. I therefore see no reason why the Council’s guidance
should not apply in this case.
8. At my visit I saw that the extension was substantially under construction and
was able to fully assess its impact on site. Although it does not take up the full
length of the outrigger and is sited below the main ridge of the property, the
dormer is nevertheless sited at a high level and has an excessive height
significantly above the ridge of the outrigger. As such, it does not reflect the
proportions of the original house or the approved extensions. It has resulted in
an overly bulky extension that appears top-heavy and is severely
disproportionate to the dwelling. Both in itself and together with the approved
rear dormer it appears unduly dominant and out of scale with the dwelling and
the area. In addition, the proposed window has a horizontal emphasis which
would not reflect the vertical proportions of the other windows in the house and
would be at odds with its character.
9. Although not visible from the street, it can be clearly seen from the rear of the
surrounding properties. Thus, by reason of its siting, size, scale and detail it
would not be a subservient extension and would result in significant harm to
the character and appearance of the dwelling and the area.
10. The benefit in terms of increased space and quality of accommodation would be
a private benefit for the appellants which would not outweigh the significant
harm I have identified to the wider area.
Conclusion
11. For the reasons stated above, I conclude that the proposed development would
be contrary to policy DMP1 and the development plan. The appeal is
dismissed.
Sarah Colebourne
Inspector
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.