Proposed construction of single storey side/rear extension. Part first floor rear extension
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Residential Amenity
Character & Appearance
Extensions
Inspector’s Reasoning
Appeal Decision
Site visit made on 10 March 2020
by S Thomas BSc (hons) MSc MRTPI
an Inspector appointed by the Secretary of State
Decision date: 31 March 2020
Appeal Ref: APP/W5780/D/20/3244572
6 Wallington Road, Seven Kings, Ilford IG3 8QQ
• The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
• The appeal is made by Mr Mamun Hussain against the decision of the Council of the
London Borough of Redbridge.
• The application Ref 3224/19, dated 23 July 2019, was refused by notice dated
21 October 2019.
• The development proposed is described as proposed construction of single storey
side/rear extension. Part first floor rear extension.
Decision
1. The appeal is dismissed.
Main Issues
2. The main issues are (i) the effect of the proposal on the character and
appearance of the dwelling and on (ii) the living conditions of the occupiers of 4
Wallington Road in respect of outlook.
Reasons
3. The appeal property is semi-detached and located in a residential street of
predominantly semi-detached properties. It has a two-storey projection to the
rear and in common with the general pattern of these rear projections does not
span the width of the property at first floor level. A number of the properties
along the street also have additional single storey extensions to the rear.
4. The Housing Design Supplementary Planning Document (2019) (SPD) states
that it is important single storey extensions do not dominate the original
property and states the maximum depth from the original house for semi-
detached properties should be 3.5m. Depths greater than this would only be
acceptable where consistent with adjoining properties. In respect of first floor
rear extensions these should not project more than 3m from the original house
and the first-floor element should generally be no more than half the width of
the original rear elevation to ensure it is proportionate and subordinate to the
original dwelling.
5. The rear projection is currently subordinate to the existing dwelling. The
proposed development would infill the existing gap from the rear projection to
the side elevation of the property adjacent to 4 Wallington Road (No. 4) at both
single storey and first storey level. This would have the effect of extending the
Appeal Decision APP/W5780/D/20/3244572
2
existing rear projection across the width of the house and altering this key
feature. The proposed roof form and infilling at first floor level would appear at
odds with the character of the dwelling and visually unbalance the pair of semi-
detached properties.
6. Similarly, the single storey rear extension would span the width of the rear
elevation of the dwelling and project approximately 4m from the rear elevation
in excess of the maximum depth for single storey extensions as allowed in the
SPD. This would extend further into the garden area than neighbouring single
storey extensions and would thus be uncharacteristic. Together, the proposed
extensions would be a dominant feature and would fail to be proportionate and
subordinate to the existing dwelling. It would thus cause harm to its character
and appearance.
7. I acknowledge the existence of similar extensions at Nos 10 and 12 Wallington
Road. However, I do not have the full details and planning circumstances which
led to these being constructed. In any event, the existence of these extensions
confirms my view that the appeal scheme would be acceptable.
8. For the reasons outlined above, the proposal would cause harm to the
character and appearance of the existing dwelling and thus would be in conflict
with Policy LP30 of the Redbridge Local Plan (2018). Amongst other things, this
policy seeks that household extensions complement the character of a building,
are subordinate in terms of size and scale or height and incorporate a roof
profile sympathetic to the existing dwelling. I turn now to living conditions.
9. The neighbouring property No. 4 is located forward of the rear elevation of the
appeal property. Whilst the proposed extension would infill the current gap in
the rear projection there will still exist a separation between the side elevation
of the proposed extension and the boundary. I have considered the available
evidence and find that the proposed extension would not breach the 45-degree
line. Further, considering the separation between the extension and the
boundary and the relationship between the properties, whilst the extension
would be of a greater height and depth than allowed in the SPD, I do not find
that it would have an unacceptably overbearing effect on next door. Thus, the
proposal would not cause harm to the living conditions of the neighbouring
occupiers. In this regard, it would not conflict with Policy LP30, which also
seeks to avoid adverse impacts on neighbouring properties.
10. Whilst I acknowledge the proposed extension would improve the quality of the
living conditions for its occupants, this is not outweighed by the harm I find to
the character and appearance of the dwelling.
Conclusion
11. For the reasons outlined above, the appeal is dismissed.
Stephen Thomas
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.