Construction of a single storey rear extension, first floor side extension, creation of a front porch and formation of a hip-to-gable loft conversion comprising a rear dormer window

📊

See the success rate & inspector analytics

Free to view — just create an account, no payment needed.

Sign Up Free

Technical Issues Heatmap

Extensions
Residential Amenity
Character & Appearance

Inspector’s Reasoning

Appeal Decision Site visit made on 20 February 2018 by Helen Cassini BSc(Hons) DipTP MRTPI an Inspector appointed by the Secretary of State Decision date: 6th March 2018. Appeal Ref: APP/E5330/D/17/3187828 84 Kidbrooke Park Road, Kidbrooke SE3 0DX  The appeal is made under section 78 of the Town and Country Planning Act 1990 against a refusal to grant planning permission.  The appeal is made by Mr & Mrs McBryde against the decision of Royal Borough of Greenwich Council.  The application Ref: 17/1827/F, dated 24 May 2017, was refused by notice dated 3 August 2017.  The development proposed is the construction of a single storey rear extension, first floor side extension, creation of a front porch and formation of a hip-to-gable loft conversion comprising a rear dormer window. Decision 1. The appeal is dismissed. Procedural Matter 2. The description of the proposal has been taken from the Council’s decision notice as it provides a full and accurate description of the development. Main Issues 3. The main issues are the effect of the proposal on: (i) the living conditions of the neighbouring occupiers at 82 Kidbrooke Park Road, with particular regard to loss of daylight and sunlight; and (ii) the character and appearance of the surrounding area. Reasons Living conditions 4. As a consequence of the location of the proposed first floor side extension, rear dormer, roof alteration and front porch with regard to the neighbouring dwelling at 82 Kidbrooke Park Road, it is not considered that any of these aspects would have a significant impact on the living conditions of the neighbouring occupiers. 5. In regard of the proposed single storey rear extension, this would provide a relatively large amount of additional floor space. It would however also have a substantially greater depth than the neighbouring dwelling at No 82. 6. Given the location of the living room windows at No 82, the proximity and depth of the proposal would introduce a considerable additional built form to Appeal Decision APP/E5330/D/17/3187828 2 the other side of these windows. This would result in a loss of both daylight and sunlight, cumulating in a sense of enclosure and confinement from within the living room and, albeit to a lesser extent, from the adjoining kitchen. 7. It is therefore considered that the loss of light and sense of enclosure would tangibly diminish the living conditions of the neighbouring occupiers of No 82 to an unacceptable degree. 8. It is noted that the occupiers of No 82 have not objected to the proposal. Be that as it may, it is a function of the planning system to secure good living conditions for existing and future occupants of buildings and in this regard, for the reasons given above, the proposal falls short of this goal. 9. From the appellant’s submitted evidence, it is recognised that the occupiers at No 82 have submitted a planning application for a broadly similar scheme. At the time of the site visit it is understood that planning permission had not been granted. If the extension at No 82 was in-situ, the impact of the appeal proposal would be much reduced, in regard of loss of light and sense of enclosure. 10. If planning permission is granted for the proposal at No 82, it is acknowledged that it may be the intention of the occupiers to construct the extension. However, in reality this does not always occur or it may be that the construction of the extension next to the appeal site may not be undertaken for some time. 11. Whilst I have sympathy for the appellants in terms of their position, the adverse impact and identified harm would be a reality in the intervening period prior to determination of the planning application submitted by the occupiers at No 82. 12. It therefore follows that the proposal fails to comply with Policy 7.6 of The London Plan 2016 (TLP), Policy DH(b) of the Royal Greenwich Local Plan; Core Strategy with Detailed Policies 2014 (the CS) and guidance contained within the Royal Borough of Greenwich Residential Extensions, Basements and Conversion Guidance Supplementary Planning Document 2016 (the SPD). When taken together these policies and guidance seek, amongst other things, to ensure that development does not result in an unacceptable loss of amenity to adjacent occupiers. Character and appearance 13. The appeal site accommodates a 2-storey semi-detached dwelling, located adjacent to a disused, brick built substation. The majority of dwellings within the locality are 2-storey semi-detached design. However, some variety in terms of design was evident, including the presence of dwellings which have hip to gable roof alterations. 14. The proposed rear dormer, although relatively substantial in scale, would be largely screened from public views and would be of a similar design to the existing dormer located on the rear roof slope at No 72. As already identified, gable roofs are a feature within the immediate locality. Whilst the proposed gable roof would be visible from within the street scene it is not considered that it would represent an overly dominant or imposing feature. In regard of the proposed front porch, this would be of similar dimensions to the existing, with only a slight variation in design. Accordingly, no harm to the character and Appeal Decision APP/E5330/D/17/3187828 3 appearance of the surrounding area is found in respect of these elements of the proposal. 15. In relation to the first floor side extension, this would be located above the existing garage. It is acknowledged that on the submitted drawings, this space is currently utilised as an office and that the proposal includes the replacement of the garage door with a window. The existing set back of approximately 300 millimetres would remain, as depicted on submitted proposed plans and elevations drawing1. 16. The proposed side extension would be set back from the front elevation and set in from the side boundary. On this basis, and given the adjacent disused substation, it would be designed in a way that would avoid a potential terracing effect. In addition, the proposed external materials and windows would match those on the host dwelling. Accordingly, the side extension would be a relatively modest and sympathetically designed feature which would appear as a subservient addition to the host dwelling. Furthermore, given the variance in terms of design of existing dwellings, it would also have a satisfactory appearance in the street scene. 17. The proposal would therefore accord with Policies 7.4 and 7.6 of TLP, Policies DH1 and DH(a) of the CS and guidance within the SPD. When taken together these policies and guidance seek, amongst other things, to ensure that new development is of a high standard of design and respects and relates to the character and context of the area in which it is proposed. Conclusion 18. No harm with regard to character and appearance has been identified. However, the harm with regard to the effect on the living conditions of the neighbouring occupiers at 82 Kidbrooke Park Road is decisive. 19. Accordingly, for the reasons given above, and taking account of all matters raised, I conclude that the appeal should be dismissed. Helen Cassini INSPECTOR 1 Drawing reference VCF/152/02 Rev A
Expert Representation

Don't leave your appeal to chance.

Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.

Get Free Review How it works →