Erection of two storey side and two storey part single storey rear extension and internal alteration
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Residential Amenity
Character & Appearance
Extensions
Inspector’s Reasoning
Appeal Decision
Site visit made on 23 October 2017
by Helen Cassini BSc(Hons) DipTP MRTPI
an Inspector appointed by the Secretary of State for Communities and Local Government
Decision date: 06 November 2017
Appeal Ref: APP/A5270/D/17/3180080
55A St Andrews Road, Acton W3 7NF
The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
The appeal is made by Mr Mohamed Dawood Younis against the decision of the Council
of the London Borough of Ealing.
The application Ref: 171919HH, dated 18 April 2017, was refused by notice dated
13 June 2017.
The development proposed is the erection of two storey side and two storey part single
storey rear extension and internal alteration.
Decision
1. The appeal is dismissed.
Main Issues
2. The main issues of the appeal are the effect of the proposal on:
(i) the character and appearance of the surrounding area; and
(ii) the living conditions of the neighbouring occupiers at 55 St Andrews Road,
with particular regard to loss of sunlight, outlook and sense of enclosure.
Reasons
Character and appearance
3. The appeal site is located on the western side of St Andrews Road, the
character of which is predominately residential. The appeal property is the
result of a two storey side and rear extension to 55 St Andrews Road which
was granted planning permission in 20081. A Certificate of Lawfulness was
approved2 in 2016 to allow use of the extension as a separate dwelling house.
A further planning application for a single storey rear/side infill extension and
part two storey rear extension was refused planning permission in 20113 due to
the proposal representing an incongruous form of over development of the site.
Whilst no details in relation to this application have been provided, the Council
in their submitted evidence, state that the proposal which is the subject of the
appeal before me is larger than the scheme refused in 2011.
4. The appeal property is located within a modest plot. The two–storey extension
on the front elevation would follow the existing building line and would be of a
1 Council reference P/2008/0544
2 Council reference 164841CPE
3 Council reference PP/2010/2037
Appeal Decision APP/A5270/D/17/3180080
2
similar height. In regard of the side elevation, this would be set in
approximately 20 centimetres from the side boundary. Turning my attention to
the rear elevation, the hipped roof would be set down approximately 1 metre
from the existing rear ridge line, with the ground floor aspect being the whole
width of the rear of the host property.
5. Given the proposed height and depth, the extension would represent a sizeable
addition which would dominate the relatively modest proportions of the host
property. As such, the extension would be seen as an unduly dominant and
incongruous addition within a relatively cramped plot. As such, the proposal
would fail to remain subservient to the host property.
6. In these circumstances, whilst reasonably localised in its extent, the effect of
the proposal would be to unacceptably diminish the character and appearance
of the host property, with consequent harm to the character and appearance of
the surrounding area. The appeal scheme therefore runs contrary to the
design aims of Policies 7.4 and 7B of the London Borough of Ealing
Development Management Development Plan Document 2013 (the DPD),
Policies 7.4 and 7.6 of The London Plan 2016 (TLP) and guidance contained
within the Interim Supplementary Planning Document 4 – Residential
Extensions (the SPD).
7. The proposal would also run contrary to one of the National Planning Policy
Framework’s (the Framework) core planning principles of seeking to secure
high quality design.
Living conditions
8. The proposed rear ground floor, single storey extension would have a depth of
approximately 4.5 metres and a height of some 3 metres. Given the proximity
of No 55, and the proposed depth of the ground floor extension, it is considered
that the scheme would appear as an overbearing and intrusive feature which
would reduce the degree of outlook experienced from the ground floor
habitable rooms of No 55. This would subsequently result in an unacceptable
sense of enclosure.
9. In addition, given the depth and height, the level of sunlight experienced in the
rear outdoor amenity space of No 55 would be impacted upon. It is noted that
the appellant contends that the proposal would comply with the Building
Research Establishment (BRE) guidelines that at least 50% of areas such as
rear gardens should received a minimum of 2 hours of sunlight on
21 March each year. No calculations in regard of this guidance have been
provided in relation to the proposal. As such, I am therefore unable to
confidently ascertain that adequate levels of sunlight would be experienced by
the neighbouring occupiers at No 55.
10. In assessing the scheme against the existing and proposed site circumstances,
it is considered that the proposal would harm the living conditions of the
neighbouring occupiers at No 55 regard to a sense of enclosure, outlook and
impact on sunlight. As such, the proposal fails to accord with the overall
amenity protection aims of Policies 7.4 and 7B of the DPD, Policies 7.4 and 7.6
of TLP and guidance contained within the SPD.
Appeal Decision APP/A5270/D/17/3180080
3
Conclusion
11. For the reasons given above, and having regard to all other matters raised, I
conclude that the appeal should be dismissed.
Helen Cassini
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.