Demolition of existing single storey rear extension and erection of two storey rear extension (revised scheme)
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Green Belt Policy
Character & Appearance
Policy Weight
Inspector’s Reasoning
Appeal Decision
Site visit made on 12 September 2017
by Mrs Zoё Hill BA(Hons) Dip Bldg Cons(RICS) MRTPI IHBC
an Inspector appointed by the Secretary of State for Communities and Local Government
Decision date: 25 September 2017
Appeal Ref: APP/P4415/D/17/3178644
1 The Avenue, Carr, Rotherham S66 8PP
The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
The appeal is made by Mr S Smith against the decision of Rotherham Metropolitan
Borough Council.
The application Ref: RB2017/0566, dated 7 April 2017, was refused by notice dated
5 June 2017.
The development proposed is described as the demolition of existing single storey rear
extension and erection of two storey rear extension (revised scheme).
Decision
1. The appeal is dismissed.
Main Issues
2. The main issues in this case are:
(a) Whether the proposal would be inappropriate development in the Green
Belt having regard to the National Planning Policy Framework (the
Framework) and any relevant development plan policies;
(b) The effect on the purposes of the Green Belt and on openness;
(c) The effect of the proposal on the character and appearance of the area
having regard to the approved scheme; and,
(d) Would the harm by reason of inappropriateness if so found, and any
other harm, be clearly outweighed by other considerations. If so, would
this amount to the very special circumstances required to justify the
proposal.
Reasons
Green Belt
3. The appeal proposal relates to a two storey hipped roof extension situated at
the rear of 1 The Avenue which is a semi-detached property. The proposed
extension would be set in from the boundary with the adjoining property in
order to preserve the daylight and outlook for the occupiers of that house.
4. It is undisputed that the appeal sites lies within the Green Belt. In this location
development is restricted to a number of purposes in both local and national
Appeal Decision APP/P4415/D/17/3178644
2
planning policy. The extension or alteration of a building is not inappropriate
provided that it does not result in disproportionate additions over and above
the size of the original building.
5. In considering the appeal extension I accept that the Framework does not
define what is or is not disproportionate. Nor does Policy CS 4 of the
Rotherham local plan - Core Strategy 2013-2028 (adopted in September 2014)
(the CS) which establishes that the Rotherham Green Belt will be protected
from inappropriate development. Policy ENV1.3 of the Rotherham Unitary
Development Plan (1999) which was taken forward as part of the Local Plan,
explains that extensions to existing dwellings in the Green Belt will be only
permitted where the extension represents a minor addition to the original
dwelling and is so sited and designed to reflect the architectural style of the
original dwelling. It also makes it clear that the Council will have regard to
compatibility with detailed Supplementary Planning Guidance (SPG) on the size
design and scale of such extensions.
6. The Council’s Supplementary Planning Document ‘Development in the Green
Belt’ (2013) (SPD) replaces an earlier SPG. It sets out that an extension
should not exceed more than 33% of the volume of the original building and
explains how this will be calculated. It explains that an extension of more than
33% would constitute a disproportionate extension, represent inappropriate
development and therefore very special circumstances will need to be
demonstrated. It also explains that even if the 33% limit is adhered to the
size, form and materials must also be suitable in relation to the host building.
The SPD is clearly related to development plan policy and largely reflects the
Framework. It is therefore a matter to which I attach significant weight.
7. Whilst there is nothing in the Framework to specify this volume of addition, it
seems to me a reasonable level to prevent disproportionate additions and
provides for consistency in local decision making.
8. The proposal does not adhere to the local policy threshold and, as an extension
of some 39%, it seems to me it represents a disproportionate extension. Thus,
I conclude that the development represents inappropriate development in the
Green Belt.
Other Green Belt Matters including Openness
9. The proposed extension would not particularly impact on the purposes of the
Green Belt insofar as Green Belts seek to: check unrestricted sprawl; prevent
merging of neighbouring towns; safeguard the countryside from encroachment;
preserve the setting and special character of historic towns; and, assist in
urban regeneration.
10. However, the proposed extension would create additional built volume and so,
whether or not the extension is seen with other buildings, the development
would impinge on openness which is one of the essential characteristics of the
Green Belt. This harm counts against the scheme.
Character and Appearance
11. The officer’s report makes it clear that the fall-back scheme (RB2016/00911)
was specifically designed by the appellant to adhere to the 33% threshold
having been told an initial scheme would be refused because of its size. That
extant scheme is not of a particularly good design in relation to the character
Appeal Decision APP/P4415/D/17/3178644
3
of the host property, nonetheless the appellant sought it and the Council
approved it in September 2016 thereby confirming the design to be acceptable.
12. There is no evidence before me to demonstrate why the flat roof could not be
built to be acceptable in maintenance terms. The appeal scheme represents a
more sympathetic design which would better reflect the character and
appearance of the host property than the extant, flat roofed, scheme although
the awkward and uncharacteristic chamfered corner near to the attached
property would remain. However, this is not a matter which I consider
represents a ‘very special circumstance’ as it simply improves upon something
which has already been considered to be acceptable such that it has relatively
recently gained planning permission.
13. Further, whilst the SPD sets out some flexibility to the 33% threshold, it
explains the type of circumstance under which the threshold might be
exceeded but none of those circumstances apply here. Notably, the dwelling is
not particularly small and currently has three first floor bedrooms and a first
floor bathroom. Thus, this case relates to a simple proposal to extend an
existing dwelling rather than exceptionally bringing a small house up to modern
standards.
Planning Balance
14. I conclude that the harm by reason of inappropriateness and harm to openness
is not clearly outweighed by other considerations such as to amount to the very
special circumstances required to justify the proposal. The appeal is therefore
dismissed.
Z H R Hill
Inspector
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.