Single storey rear extension

📊

See the success rate & inspector analytics

Free to view — just create an account, no payment needed.

Sign Up Free

Technical Issues Heatmap

Residential Amenity
Extensions
Policy Weight

Inspector’s Reasoning

Appeal Decision Site visit made on 5 September 2017 by Caroline Mulloy BSc (Hons) DipTP MRTPI an Inspector appointed by the Secretary of State for Communities and Local Government Decision date: 11 October 2017 Appeal Ref: APP/L5240/D/17/3177882 32 Gibson’s Hill, Norbury, London SW16 3JP  The appeal is made under section 78 of the Town and Country Planning Act 1990 against a refusal to grant planning permission.  The appeal is made by Mrs Sophia Baig against the decision of the Council of the London Borough of Croydon.  The application Ref 17/00348/HSE, dated 9 January 2017, was refused by notice dated 16 March 2017.  The development proposed is single storey rear extension. Decision 1. The appeal is dismissed. Main Issue 2. The main issue is the effect of the proposal on the living conditions of the occupiers of number 34 Gibson’s Hill with particular regard to outlook. Reasons 3. The appeal site is a two-storey detached house situated on the eastern side of Gibson’s Hill within a predominately residential area. Paragraph 6.2 of the Council’s Residential Extensions and Alterations Supplementary Planning Document No2 (SPD2) states that the maximum acceptable projection beyond the rear elevation of the neighbouring building for terraced and semi-detached dwellings is generally 3m, although on well separated detached dwellings, a larger extension may be permissible. 4. There is a good distance between the appeal property and number 30 Gibson’s Hill due to the presence of an access road. However, the appeal property sits in close proximity to the boundary with Number 34 Gibson’s Hill (No 34) which sits approximately 1m away from the common boundary. Consequently, whilst detached, I do not consider that the appeal property and No 34 are well spaced. 5. It is proposed to erect a rear extension which would be situated approximately 0.4m from the boundary of the appeal site with No 34. It would extend approximately 4m from the existing main rear elevation; however, it would extend around 6m in length from the rear of the original side projection at a height of around 2.6m close to the boundary. Appeal Decision APP/L5240/D/17/3177882 2 6. The French windows of No 34 are situated on the other side of the property and occupiers would, therefore, retain sufficient outlook over their own garden and the rear section of the appeal property’s garden. 7. Planning permission1 has been granted for a similar proposal for a rear extension but set in from the common boundary in line with the main side elevation of the existing house. The approved extension was partially built at the time of my site visit. 8. The outlook from the patio area of the garden of No 34 would be curtailed to a degree on the boundary with the appeal property due to the presence of the approved extension. However, the side elevation of the approved extension would be 1.4m in from the boundary of the appeal site thus creating a sense of space between the extension and No 34. 9. I acknowledge that the rear gardens are a reasonable size and that a proportion of the garden of No 34 would remain unenclosed. However, the proposed extension would sit only approximately 0.4m in from the common boundary and enclose the section of the garden where occupiers are most likely to sit out. Whilst only single storey, occupiers would, nevertheless, be faced with a long and substantial blank brick elevation in very close proximity to their boundary which would create a sense of enclosure and have a dominating effect. There is currently a relatively low post and rail fence and some limited vegetation along the boundary of No 34 which would not sufficiently mitigate the harmful impact. 10. For the reasons stated, I conclude that the proposal would harm the living conditions of the occupiers of No 34 with specific reference to outlook. It would, therefore, be contrary to Saved Policy UD8 of the Croydon Replacement Unitary Development Plan (2006) and Policy 7.6 of the London Plan 2016 which together seek to ensure that buildings and structures do not cause unacceptable harm to the amenity of surrounding land and building and that the privacy and amenity of occupiers of surrounding buildings are protected from undue visual intrusion and loss of privacy. Conflict also arises with SPD2. Conclusion 11. For the reasons stated and taking all other considerations into account the appeal should be dismissed. Caroline Mulloy Inspector 1 Planning application reference 16/03641/P
Expert Representation

Don't leave your appeal to chance.

Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.

Get Free Review How it works →