Single and two storey side to rear extension with front bay window (demolition of attached garage)
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Character & Appearance
Extensions
Residential Amenity
Inspector’s Reasoning
Appeal Decision
Site visit made on 10 August 2017
by D Cramond BSc MRTPI
an Inspector appointed by the Secretary of State for Communities and Local Government
Decision date: 18 August 2017
Appeal Ref: APP/M5450/D/17/3177174
1a Mount Drive, Harrow, HA2 7RW
The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
The appeal is made by Mr S Siddiqui against the decision of the Council of the London
Borough of Harrow.
The application Ref P/1295/17, dated 20 March 2017, was refused by notice dated 15
May 2017.
The development proposed is a single and two storey side to rear extension with front
bay window (demolition of attached garage).
Decision
1. The appeal is allowed and planning permission is granted for a single and two
storey side to rear extension with front bay window (demolition of attached
garage) at 1a Mount Drive, Harrow, HA2 7RW in accordance with the terms of
the application, Ref P/1295/17, dated 20 March 2017, subject to the following
conditions:
1. The development hereby permitted shall begin not later than three years
from the date of this decision.
2. The materials to be used in the construction of the external surfaces of the
development hereby permitted shall match those used in the existing
building.
3. The development hereby permitted shall be carried out in accordance with
the following approved plans: SJ.PA.2015.105RevP02, 106RevP02,
107RevP02, 108RevP02 & 109Rev P02.
4. Prior to first occupation of the development hereby permitted the windows
in the ground floor north western flank elevation of the proposed
development shall:
(a) be of purpose-made obscure glass,
(b) be permanently fixed closed below a height of 1.7m above finished
floor level,
and shall thereafter be retained in that form.
Main Issue
2. The main issue is the effect of the proposal on the character and appearance of
the host property and the locality.
Appeal Decision APP/M5450/D/17/3177174
2
Reasons
Character and appearance
3. The appeal property is on a wedge shaped plot and is a detached dwelling of
more recent origin than most in this area. The locality is of established
residential character and pleasing appearance in which bay fronted homes,
generally semi-detached with hipped roofs, prevail. The proposal is as
described above and would primarily provide for additional living and bedroom
accommodation.
4. A considerable portion of the proposed works has planning permission via a
December 2016 approval (Ref P/5103/16). The appeal plans seek to enlarge
and ‘bring forward’ the first floor level along with a bay window and to roof
over this larger side extension with a ridge height continuing from the main
home. In essence the Council is concerned that this would be an overly bulky
extension with an unsympathetic design giving consequent impact upon
immediate and wider aesthetic qualities. Certainly the frequently used
approach for visually successful side extensions would encompass upper level
set-backs and a lower subservient roof form. However to my mind there are a
number of reasons why this norm would not need to be necessarily adopted as
a design solution on this dwelling.
5. As well as being on an unusual shaped plot the host property is of a different
design to those in the neighbourhood in that it has a much more modest bay
feature which the scheme would duplicate; the frontage work would be more
visually modest than if the same exercise was undertaken on other properties.
The roof would continue to have a main hip of the style found locally and the
overall length of the main ridge when extended on this detached home would
be less than that found prevailing locally as it is generally semi-detached pairs
which are spanned. Furthermore the appeal dwelling is at lower floor level
than its parallel neighbour and has an overall roof plane and slopes which are
shorter and lower than the dwellings to the south east or across the road. This
is not a development which would catch or jar on the eye by standing overly
proud. A degree of symmetry being formed by the existing and planned bays
would not be out of place when bay duplication is a characteristic of the area.
6. In addition one of the reasons in seeking a set back is often to prevent or
lessen any ‘terracing effect’ however in this instance the appeal property is at
the end of a run of homes and then abuts, on a diagonal, rear gardens from
properties around the corner. The result is that the extension, at its frontage,
would have an appreciable gap to the nearest boundary, there would be no
question of terracing, and there would be no crowding towards two streets as
one can envisage on a true corner plot.
7. Policy DM1 of the Development Management Policies Development Plan
Document, Policy CS1 of the Harrow Core Strategy and Policies 7.4 and 7.6 of
the London Plan, taken together and amongst other matters, call for
development to be appropriately designed for its site and setting, of a suitable
form and character and protective of local distinctiveness. I conclude that the
appeal scheme would not run contrary to these policies which share similar
objectives to the Council’s Supplementary Planning Document: Residential
Design Guide (2010), a document which cannot be expected to cover in
detail every eventuality.
Appeal Decision APP/M5450/D/17/3177174
3
Conditions
8. The Council suggests the standard commencement condition along with the
requirement for materials to match the existing building. I agree this latter
condition would be appropriate in the interests of visual amenity. I also agree
that there should be a condition that works are to be carried out in accordance
with listed, approved, plans; to provide certainty. The use of obscure glazing
with opening restrictions is advocated by the Council for the side ground floor
windows and I would agree with this for the protection of neighbours’ privacy.
Despite the case made by the Council I see no need for specific restrictions on
the insertion of other openings on this relevant flank as any such works would
require specific planning permission and could be judged on their merits.
Overall conclusion
9. For the reasons given above I conclude that the appeal proposal would not
have unacceptable adverse effects on the character and appearance of the host
property or the locality. Accordingly the appeal is allowed.
D Cramond
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.