Dormer loft conversion and French Doors with Juliette balcony
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Extensions
Residential Amenity
Character & Appearance
Inspector’s Reasoning
Appeal Decision
Site visit made on 22 March 2017
by Andrew Dawe BSc(Hons) MSc MPhil MRTPI
an Inspector appointed by the Secretary of State for Communities and Local Government
Decision date: 07 April 2017
Appeal Ref: APP/N5090/D/16/3165050
1 Pank Avenue, New Barnet, Barnet EN5 1NF
The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
The appeal is made by Mr Steven Glynne against the decision of the Council of the
London Borough of Barnet.
The application Ref 16/4941/RCU, dated 26 July 2016, was refused by notice dated
4 October 2016.
The development is dormer loft conversion and French Doors with Juliette balcony.
Decision
1. The appeal is allowed and planning permission is granted for dormer loft
conversion at 1 Pank Avenue, New Barnet, Barnet EN5 1NF in accordance with
the terms of the application, Ref 16/4941/RCU, dated 26 July 2016, subject to
the following conditions:
i) The Juliette balcony shown on Dwg Nos sdc/pan/04PL and sdc/pan/06PL,
relating to the southern side elevation of the development hereby
permitted shall not be installed. Furthermore, within 3 months of the
date of this decision, the French doors on that same southern elevation
of the development hereby permitted shall be removed and replaced
with tile hanging to match the remainder of that dormer extension.
ii) Those windows shown on the elevation drawing No sdc/pan/04PL
relating to the northern side elevation of the development hereby
permitted shall not be implemented but instead, of those windows (one
for a bedroom and the other for a bathroom) that have been installed in
that elevation as shown on drawing No sdc/pan/06PL, within 3 months of
the date of this decision, that relating to the bedroom shall be removed
and replaced with tile hanging to match the remainder of that dormer
extension; and that relating to the bathroom shall be fitted with
obscured glazing, with no part of that window that is less than 1.7
metres above the floor level of the room in which it is installed being
capable of being opened, and retained as such thereafter.
iii) Notwithstanding the provisions of the Town and Country Planning
(General Permitted Development) (England) Order 2015 (or any order
revoking and re-enacting that Order with or without modification), no
windows or doors, other than those expressly authorised by this
permission, shall be constructed on the north or south facing side
elevations of the development hereby permitted.
Appeal Decision APP/N5090/D/16/3165050
2
Procedural Matters
2. The description of development in the decision paragraph above differs from
that in the fourth bullet of the above header to reflect the removal of the
French Doors with Juliette balcony, as suggested by the appellant and secured
in the above conditions to address issues of overlooking of neighbouring
properties. As I have explained in my reasoning, such an approach would not
prejudice the Council or neighbouring residents. Furthermore, the number and
positioning of windows shown in the northern side elevation of Dwg No
sdc/pan/04PL does not reflect the floor layout plan, Dwg No sdc/pan/06PL. I
consider that this discrepancy, also ensuring only the bathroom window shown
on the latter drawing in that north elevation is retained, as explained in my
reasoning below, can be addressed by a condition without prejudicing any of
the parties concerned.
3. The Council, in its decision notice refers to its Residential Design Guidance
Supplementary Planning Document (the SPD) to which I have applied some
weight due to its role in supporting the relevant development plan policies.
Main Issue
4. The main issue is the effect of the development on the character and
appearance of the host dwelling and surrounding area.
Reasons
5. The development, with the exception of the proposed Juliette balcony, has
been completed. Furthermore, two windows have been inserted in the
northern side elevation instead of the three shown on the elevation drawing.
Those two windows do however accord with the floor plan drawing submitted.
6. The development completely alters the original roof form of the dwelling at the
rear and sides with a large extent of the original pitched roof having been
replaced with large dormers wrapping around from the sides to the rear.
However, the front elevation and hipped roof form remains unaltered. As such,
the side dormers are set well back from the front elevation of the dwelling and
so partially screened from view, to varying degrees, on the approaches to the
site along Pank Avenue by that original front roof slope. They are also clad in
tiles that complement those of the front roof area.
7. The dwelling is also set back to some degree from the road and of relatively
modest height compared with many other originally full two storey dwellings in
the street. The southern dormer is also obscured to some extent by the low
pitched roof at the front of the existing otherwise flat roof single storey side
extension on that side of the dwelling. The French doors in the southern
dormer are therefore also not clearly visible from the street. On the approach
from the north, the dwelling at No 3 also screens a large part of the northern
dormer.
8. Although the side dormers are clearly visible from the street, for the above
reasons they are not dominant features of the dwelling in the context of the
streetscene and as such do not have a jarring or incongruous impact in that
important respect. That is also in the context of an already fairly varied street
scene in terms of building designs, including the dwelling opposite at No 2
which has highly prominent, large side dormers at a higher level due to being
an originally 2-storey dwelling.
Appeal Decision APP/N5090/D/16/3165050
3
9. The rear ends of the side dormers and the particularly large rear dormer, whilst
representing bulky and roof altering additions, are not widely visible from the
surrounding area other than to varying degrees from neighbouring dwellings.
In this respect, from Eversleigh Road to the north, it is only glimpsed through
gaps between buildings. However, being set well back from that road, it is not
a prominent or dominating feature. Furthermore, the tile cladding provides it
with some degree of reference to the original house in terms of roofing
materials and it is also again seen in the context of the fairly varied building
designs in the vicinity.
10. Whilst such extensions, as referred to in the SPD, would often not be
acceptable, the circumstances in this case are such that, for the above reasons,
the development does not cause unacceptable harm to the character and
appearance of the host dwelling or the surrounding area. As such, it accords
with policies 3.5 and 7.6 of the London Plan, policy CS5 of Barnet’s Local Plan
(Core Strategy) and policy DM01 of the Barnet’s Local Plan (Development
Management Policies), which together in respect of this issue require
development to respect local context and distinctive local character, and to
represent high quality design. It would also not be at odds with the general
principle set out in the SPD of seeking to protect Barnet’s character.
11. I have also had regard to concerns raised relating to overlooking and loss of
privacy to residents living at No 3 Pank Avenue and No 42 Longmore Avenue.
There would currently be potential for the currently obscure glazed French
doors in the side of the southern dormer, when open, to allow significant direct
overlooking to the rear of the adjacent dwellings and gardens of Longmore
Avenue immediately to the south of the site. The proximity to those properties
would be likely to result in this causing harmful loss of privacy. Likewise, the
close proximity of the existing bedroom window in the north dormer to a
ground floor habitable room window on the side of No 3 would have the
potential to cause a harmful level of overlooking and loss of privacy to the
residents of that property.
12. In respect of this issue, the appellant wishes to amend the scheme so as to
remove the side French doors on the southern dormer extension and the
bedroom window in the northern dormer. With the former, this would also
prevent access to and therefore overlooking from the flat roof of the side
extension. Similarly the securing of the bathroom window on the northern
elevation with obscured glazing and fixed below 1.7 metres above floor level,
would further prevent overlooking into the side habitable room window of No 3.
As those changes would address the issue relating to overlooking and loss of
privacy of neighbouring residents, without detracting from the appearance of
the development, I am satisfied that they would be appropriate and would not
prejudice either the Council or those neighbouring residents by incorporating
them. Although I have not received amended plans to reflect these changes,
they can be secured by condition.
13. The Council has suggested five conditions in its officer report that it considers
would be appropriate were I minded to allow the appeal. I have considered
these in the light of advice in the Government’s Planning Practice Guidance and
amended some of the wording, omitted three and added one. Notwithstanding
the outstanding requirements relating to the fenestration on the north and
south elevations, the development is completed and so the suggested
conditions concerning the time period for commencement, carrying out the
Appeal Decision APP/N5090/D/16/3165050
4
development in accordance with the approved plans and requiring the materials
to match those in the existing building, where they already do so, are
unnecessary.
14. In the interests of the privacy of those residents living to the north and south
of the site, the Council has suggested a condition to require all of the north and
south fenestration on the dormers to be obscure glazed and fixed below 1.7
metres above floor level. However, the conditions suggested by the appellant
and referred to above, albeit with amended wording, concerning the north and
south dormer fenestration, including removal of all but the bathroom window,
would achieve the same aim. As such they would be reasonable and necessary
in order to address this issue.
15. In the interests of the character and appearance of the host dwelling and
surrounding area, it would also be necessary for the above conditions to secure
materials to match the rest of the dormer once the existing fenestration has
been removed. To avoid any potential future unacceptable levels of
overlooking and loss of privacy to those neighbouring residents, a condition to
prevent any windows or doors in the north or south elevations of the
development other than those authorised would also be necessary.
Conclusion
16. For the reasons given above, I conclude that the appeal should be allowed.
Andrew Dawe
INSPECTOR
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.