Single storey rear and side infill extension
📊
See the success rate & inspector analytics
Free to view — just create an account, no payment needed.
Sign Up FreeTechnical Issues Heatmap
Residential Amenity
Extensions
Character & Appearance
Inspector’s Reasoning
Appeal Decision
Site visit made on 6 September 2016
by Helen Hockenhull BA(Hons) B.Pl MRTPI
an Inspector appointed by the Secretary of State for Communities and Local Government
Decision date: 22 September 2016
Appeal Ref: APP/G5180/D/16/3154588
59 Mooreland Road, Bromley BR1 3RD
The appeal is made under section 78 of the Town and Country Planning Act 1990
against a refusal to grant planning permission.
The appeal is made by Mr Andrew Shaw against the decision of the Council of the
London Borough of Bromley.
The application Ref C/16/01062/FULL6, dated 23 February 2016, was refused by notice
dated 26 April 2016.
The development proposed is a single storey rear and side infill extension.
Decision
1. The appeal is dismissed.
Main Issue
2. The main issue in this case is the effect of the development on the living
conditions of the occupiers of the neighbouring dwelling with particular regard
to outlook.
Reasons
3. The appeal property forms a two storey Victorian mid terrace dwelling with an
existing single storey rear projection originally built with the house. The appeal
proposes the replacement of this rear extension with the construction of a
single storey side /rear extension with a total projection of about 6 metres.
This would extend across the full width of the property for a distance of around
4 metres and then step in from the side boundary with the neighbouring
property at No. 57 by approximately 0.7 metres for the remaining 2 metres.
The extension would have a pitched roof with an eaves height just over 2.4
metres.
4. No. 57 Mooreland Road also has a similar originally built single storey rear
projection with a side window serving a kitchen facing the side boundary fence.
In addition this property has a glazed door opening on the main rear elevation
close to the shared boundary which provides access to the dining area.
5. The proposed extension would project above the side boundary fence by
around 0.4 metres. The height of the proposed extension together with its
proximity to the side boundary and its depth would result in a dominant form of
development detrimental to the visual amenities of the occupants of the
neighbouring dwelling. It would adversely affect the outlook from the side
Appeal Decision APP/G5180/D/16/3154588
2
kitchen window of the rear extension and increase the sense of enclosure to
this window and the glazed door opening in the rear elevation.
6. In respect of No. 61 Mooreland Road, the extension would project
approximately 0.8 metre further than the existing single storey extension. The
Council raises no concern with regard the impact on this property. I concur
with this assessment.
7. The appellant has brought my attention to an appeal decision for a rear
extension at a property on Derwent Avenue, Pinner1. However this proposal
related to a two storey side extension above an existing side garage with a two
storey extension behind and not a single storey rear/side extension as in the
appeal case before me. Whilst I note that this scheme had no flank wall
windows, as in the case before me, in other respects, such as the style of
property, an extended bungalow, this proposal would not be directly
comparable. I have therefore considered the appeal case on its individual
merits.
8. I note that that planning permission has been refused for a previous similar
proposal at the appeal dwelling and that the current appeal scheme attempts
to address the previous reasons for refusal. I acknowledge that the proposal in
many respects meets the requirements of the Council’s Residential Design
Supplementary Planning Guidance (SPD) in particular it respects the
composition of the host building in rhythm of form and detail. In addition the
extension, located to the rear of the appeal property, would have no impact on
the street scene or the character and appearance of the area. The scheme
removes side window openings on the shared boundary so that the privacy of
the occupants of the neighbouring property would be maintained and
appropriate rear amenity space would be retained to serve the property.
9. However, whilst the above factors provide support to the scheme, they do not
outweigh the harm to the living conditions of the occupiers of the neighbouring
dwelling through poor outlook. The proposal would therefore not comply with
Policies H8 or BE1 of the Bromley Unitary Development Plan 2006 or the
Residential Design SPD which aim to achieve a high standard of design and
protect the amenity of occupiers of adjoining properties. I consider these
policies to be generally consistent with the National Planning Policy Framework
(the Framework) in particular paragraph 17 which aims to secure high quality
design and a good standard of amenity for all existing and future occupants of
land and buildings.
Conclusion
10. For the reasons given above and having regard to all other matters raised, I
dismiss this appeal.
Helen Hockenhull
INSPECTOR
1 APP/M5450/D/15 3005566
Expert Representation
Don't leave your appeal to chance.
Inspectors are inconsistent. We build a technical defense using precedents from our 182,000+ case archive.
No win, no fee Householder representation — you only pay if you win.